Setting the Outputs
66
FQ Short Manual
Obtaining Individual Judgement Results
Up to three judgement results of individual inspection items (individual judgement signals OR0 to OR31) can
be assigned to terminals OUT0 to OUT2 and output to external devices.
Wiring
Example: Signals are assigned to terminals OUT0 to OUT2 as shown below.
• OUT0: Inspection number 2 (OR2)
• OUT1: Inspection number 5 (OR5)
• OUT2: Inspection number 14 (OR14)
As described above, if terminals OUT0 to OUT2 are all assigned to individual judgement output signals, the
BUSY signal and ERROR signal assigned as the default settings will no longer be output.
Output terminal
Output signals that can be assigned
OUT0
• OR (Total judgement)...(default)
• OR0 (Item 0 judgement) to OR31 (Item 31 judgement)
OUT1
• BUSY (default)
• OR0 (Item 0 judgement) to OR31 (Item 31 judgement)
OUT2
• ERROR (default)
• OR0 (Item 0 judgement) to OR31 (Item 31 judgement)
Color
Signal
Description
The signals shown at the left are used.
Refer to the following information for signal wiring.
2-3 Wiring: p. 15
Black
OUT0 (OR2)
Outputs the judgement for
OR2.
Orange
OUT1 (OR5)
Outputs the judgement for
OR5.
Light
blue
OUT2 (OR14)
Outputs the judgement for
OR14.