7
External
Reference
Tables
214
Measurement
FZ3 User's Manual
7
Average B component value
Get only
0 to 255
8
Color difference
Get only
0 to 442
9
Color deviation
Get only
0 to 219.9705
10
Density average
(for monochrome cameras only)
Get only
0.000 to 255.000
11
Density deviation value
(for monochrome cameras only)
Get only
0.000 to 127.000
12
Reference average value
Get only
0.000 to 255.000
13
Reference deviation value
Get only
0.000 to 127.000
103
Reflect to overall judgement
Set/Get
0: ON
1: OFF
120
Normalization
Set/Get
0: OFF
1: ON
121
Reference color R
Set/Get
0 to 255
122
Reference color G
Set/Get
0 to 255
123
Reference color B
Set/Get
0 to 255
124
Upper limit for color difference
Set/Get
0 to 442
125
Lower limit for color difference
Set/Get
0 to 442
126
Upper limit for color deviation
Set/Get
0 to 221
127
Lower limit for color deviation
Set/Get
0 to 221
128
Reference density average
Set/Get
0 to 255
129
Reference density deviation
Set/Get
0 to 127
130
Upper limit for density average
(for monochrome cameras only)
Set/Get
0 to 255
131
Lower limit for density average
(for monochrome cameras only)
Set/Get
0 to 255
132
Upper limit for density deviation
(for monochrome cameras only)
Set/Get
0 to 127
133
Lower limit for density deviation
(for monochrome cameras only)
Set/Get
0 to 127
Gravity and Area
No.
Data name
Set/Get
Data range
0
Judge
Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5
Area
Get only
0 to 999999999.9999
6
Gravity X
Get only
-99999.9999 to 99999.9999
7
Gravity Y
Get only
-99999.9999 to 99999.9999
8
Reference area
Get only
0 to 999999999
9
Reference X
Get only
-99999.9999 to 99999.9999
10
Reference Y
Get only
-99999.9999 to 99999.9999
101
Output Coordinates
Set/Get
0: After scroll
1: Before scroll
102
Calibration
Set/Get
0: OFF, 1: ON
103
Reflect to overall judgement
Set/Get
0: ON, 1: OFF
Acesst 1.0 6251194