3
Performing
Test
Measurement/Starting
Operation
FZ3 User's Manual
Performing Test Measurement
63
Performing Test Measurement
Test whether the intended measurement processing can be performed with the current setting
contents.Look at test results and adjust the property settings of each processing unit.
Perform measurement according to the conditions set in the displayed scene.
1.
Display the Main screen (ADJUST window).
2.
For the test conditions on the ADJUST window, set the following items.
Setting item
Description
Output
Place a check here when the measurement results on the ADJUST window are also
to be output.Remove the check when test measurement for the device only is to be
performed without results being output.
Continuous
meas.
Place a check here when continuous measurement is to be performed.
Tapping the [Measure] button starts continuous measurement.
3.
Tap [Measure] in the Toolbar.
Measurement is performed.
Note
●
With continuous measurement, the [Measure] button changes to the [Stop meas.] button during the
measurement.To stop continuous measurement, tap [Stop meas.].
4.
Check measurement results.
5.
If necessary, adjust the setting values for each processing unit again.
Moving to the property window can be done directly by tapping the button of any processing unit
set in the flow.
Acesst 1.0 6251194