Control/Output through EtherNet/IP
FZ4 User's Manual
Important
●
Set the communication module to [EtherNet/IP] before setting the communication specifications. Save the
setting to the controller and then restart the system. Furthermore, if the operation mode is set to the multi-line
random trigger mode, the communication module on line 1 must also be set to "Ethernet/IP."
Reference:
Setting the Start-up Status [Startup Setting] (p.347)
●
When using 2-line random trigger mode with the FZ4-11
/H11
series, specify different addresses for
the sending and receiving areas of line 0 and line 1.
●
After the tag data link is set, the controller automatically restarts to reflect the setting.
1.
On the Main screen, tap [System] menu
→
[Communication]
→
[EtherNet/IP].
The EtherNet/IP window is displayed.
2.
Set the following items.
Acesst 1.0 6251194