8
Appendixes
FZ4 User's Manual
FAQ
577
Tap [Data] menu - [Save to file] - [Setting data] - [Scene group data].
The window switching speed is slow.
●
When both lines are set to through display in the multi-line random trigger mode, the controller's
response time may be slow.
For Measurement
Display is not updated.
●
Measurement is given priority when the STEP signal input interval is short or continuous
measurement is being performed. As a result, the measurement results (overall judgment, image,
individual judgment in the flow display, detailed results) may not be updated. When continuous
measurement ends, the measurement results for the final measurement are displayed.
Measurement results in NG as the monochrome setting is changed to color setting on its own
●
This occurs when the monochrome processing item setting window is displayed with no image
input, such as immediately after the start-up or a scene is switched. When no image is input,
measurement NG (incompatible image) will result since it is set to process as a color image by
default.
When no image is input, do not go into the setting window and press the OK button to terminate it.
To fix the setting, have an image input, and then go into the setting window and press the OK
button to terminate it.
To fix the setting, have an image input, and then go into the setting window and press the OK
button to terminate it.
Target figure for the processing unit figure setting has disappeared
●
This occurs when image input or image compensation-related units, such as filtering, are set
between the processing unit figure setting and the unit to be changed.
Processing Items List Manual
Processing Item List > Supporting Inspection and Measurement > Processing Unit Figure Setting
Refer to the [Important] section of the aforementioned.
Judgement (JG) value is -10
●
The judgement will be -10 when there is incompatibility between the scene setting and the input
image. Could the image be a color image even though it is loaded to a scene that is set for a
monochrome camera? Please check the setting.
About Parallel Interface
Trigger signal (input signal) not accepted
●
Are the cables connected correctly?
●
Is the signal cable disconnected?
You can check the communication status in the Confirmation window.
Reference:
Checking Communication Status (Parallel Interface) (p.542)
●
Are windows other than the Main screen (the Edit Flow window, etc.) displayed?
●
Are there any setting windows open?
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......