A4 - 9
A4 Appendix Object Dictionary
GRT1-series EtherCAT Communication Unit - Operation Manual
A4-1 Object Dictio
nary
A
A4-1-
6 Sync Manage
r
Communica
tion Object
•
It indicates the RxPDOs used by this sync manager.
•
It indicates the TxPDOs used by this sync manager.
1C12 hex
Sync manager 2 PDO assignment
Sub-index 0: Number of assigned RxPDOs
Range: 00 hex to 04 hex
Unit:
−
Default: 05 hex
Attribute:
−
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
Sub-index 1: Assignment of digital outputs
Range: 1600 hex to 17FF hex
Unit:
−
Default: 1600 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Sub-index 2: Assignment of digital outputs
Range: 1600 hex to 17FF hex
Unit:
−
Default: 1601 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Sub-index 3: Assignment of digital outputs
Range: 1600 hex to 17FF hex
Unit:
−
Default: 1602 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Sub-index 4: Assignment of analog outputs
Range: 1600 hex to 17FF hex
Unit:
−
Default: 1610 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Sub-index 5: Assignment of counter outputs
Range: 1600 hex to 17FF hex
Unit:
−
Default: 1620 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
1C13 hex
Sync manager 3 PDO assignment
Sub-index 0: Number of assigned TxPDOs
Range: 00 hex to 05 hex
Unit:
−
Default: 06 hex
Attribute:
−
Size: 1 byte (U8)
Access: RW
PDO map: Not possible
Sub-index 1: Assignment of com status
Range: 1A00 hex to 1BFF hex
Unit:
−
Default: 1A00 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Sub-index 2: Assignment of digital inputs
Range: 1A00 hex to 1BFF hex
Unit:
−
Default: 1A10 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Sub-index 3: Assignment of digital inputs
Range: 1A00 hex to 1BFF hex
Unit:
−
Default: 1A11 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Sub-index 4: Assignment of digital inputs
Range: 1A00 hex to 1BFF hex
Unit:
−
Default: 1A12 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Sub-index 5: Assignment of analog inputs
Range: 1A00 hex to 1BFF hex
Unit:
−
Default: 1A20 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Sub-index 6: Assignment of analog inputs
Range: 1A00 hex to 1BFF hex
Unit:
−
Default: 1A30 hex
Attribute:
−
Size: 2 bytes (U16)
Access: RW
PDO map: Not possible
Summary of Contents for GRT1-ECT SmartSlice
Page 3: ...GRT1 series EtherCAT Communication Unit Operation Manual Revised March 2012 ...
Page 18: ...15 GRT1 series EtherCAT Communication Unit Operation Manual ...
Page 30: ...1 EtherCAT Network 1 8 GRT1 series EtherCAT Communication Unit Operation Manual ...
Page 38: ...2 EtherCAT Communication details 2 8 GRT1 series EtherCAT Communication Unit Operation Manual ...
Page 52: ...4 GRT1 ECT Details 4 10 GRT1 series EtherCAT Communication Unit Operation Manual ...
Page 76: ...6 GRT1 ECT Troubleshooting 6 12 GRT1 series EtherCAT Communication Unit Operation Manual ...
Page 136: ...A4 Appendix Object Dictionary A4 16 GRT1 series EtherCAT Communication Unit Operation Manual ...
Page 140: ...Revision 2 GRT1 ECT series EtherCAT Slave Unit User s Manual ...