Solid-state Twin Timer
H3DE-F
B-67
Ti
m
e
rs
Operation
■
Basic Operation
Time Unit Selection
The time unit display window for output ON is located on the upper-
right side of the front panel above the corresponding time unit selec-
tor.
The time unit display window for output OFF is located on the lower-
right side of the front panel below the corresponding time unit selec-
tor.
According to the setting of each time unit selector, “sec” for seconds,
“10s” for 10 seconds, “min” for minutes, or “hrs” for hours will appear
in the corresponding time unit display window.
Time Scale Selection
The time scale selector on the upper-left side of the front panel can
be set to 0.1 or 1 as a magnification coefficient.
Time Setting
Use the ON/OFF-time setting dial to set the ON/OFF time.
■
Timing Charts
Note: 1.
The reset time requires a minimum of 0.1 s.
2.
When power is supplied in flicker-ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance
of the Timer.
ON-time unit display window
OFF-time unit display window
ON-time unit selector (select
one from sec, 10s, min, or hrs)
OFF-time unit selector (select
one from sec, 10s, min, or hrs)
Time scale display window
Time scale selector
OFF-time setting dial
ON-time setting
dial
Operating
mode
Timing chart
Flicker-OFF
start
Flicker-ON
start
ON
OFF
0.1 s min.
ON
OFF
ON
OFF
ON
OFF
Power (A
1
and A
2
)
OFF indicator
Output relay: NO
15 and 18
(ON indicator)
Output relay: NC
15 and 16
t
ON
: ON set time
t
OFF
: OFF set time
0.1 s min.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Power (A
1
and A
2
)
OFF indicator
Output relay:
NO 15 and 18
(ON indicator)
Output relay: NC
15 and 16
t
ON
: ON set time
t
OFF
: OFF set time
Summary of Contents for H3DE