B-70
Solid-state Star-delta Timer
H3DE-G
Specifications
■
General
Note:
Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.
■
Time Ranges
■
Ratings
Note:
DC ripple rate: 20% max.
Item
H3DE-G
Operating mode
Star-delta operation
Operating/Reset method
Time-limit operation/Self-reset
Terminal block
Clamps two 2.5 mm
2
max. bar terminals without sleeves
Terminal screw tightening torque
0.98 N·m max. {approx. 10 kgf·cm max.}
Output type
(Star operation circuit) Relay: SPDT
(Delta operation circuit) Relay: SPDT
Mounting method
DIN track mounting (see note)
Attachment
Nameplate
Approved standards
UL508, CSA 22.2 No.14
Conforms to EN61812-1, IEC60664-1 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)
Time scale display
Star operation time ranges
x 1
1 to 12 s
x 10
10 to 120 s
Star-delta transfer time
Programmable at 0.05 s, 0.1 s, 0.25 s or 0.5 s
Rated supply voltage (see note)
24 to 230 VAC/VDC (50/60 Hz)
Operating voltage range
85% to 110% of rated supply voltage
Power reset
Minimum power-off time: 0.5 s
Reset voltage
24 VAC/DC max.
Power consumption
AC: Approx. 3 VA (1.8 W) at 230 VAC
DC: Approx. 0.8 W at 24 VDC
Control output
Contact output: 5 A at 250 VAC with resistive load (cos
φ
= 1)
5 A at 30 VDC with resistive load (cos
φ
= 1)
Ambient temperature
Operating:
−
10
°
C to 55
°
C (with no icing)
Storage:
−
25
°
C to 65
°
C (with no icing)
Ambient humidity
Operating: 35% to 85%