background image

1

H3JA

  Solid-state Timer

Economical, Compact, Plug-in Timer

Time limit operation with automatic resetting.

DIN size (36 x 36 mm), fits standard 8-pin sock-
ets.

Wide choice of supply voltages:
24, 100 to 120, 200 to 240 VAC, 24 VDC.

Dual LED indication for power and output sta-
tuses.

Large transparent setting knob.

Setting error rating almost matches that of a 48 x
48 timer.

Conforms to UL and CSA, and meets CE marking
requirements.

Ordering Information

Note:

Specify the model number, supply voltage, and rated time when ordering.

Accessories (Order Separately)

Note:

1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 Socket.

2. Hold-down Clips are sold in sets of two.

RC

Operation/resetting 

system

Time-limit contact

Mounting method

Rated time

Model

Time-limit operation/
self-resetting

SPDT

Surface mounting, flush 
mounting, and DIN track 
mounting

1 s, 3 s, 5 s, 10 s, 30 s, 
60 s, 3 min, 5 min, 10 min, 
30 min, 60 min, 3 hrs

H3JA-8A

DPDT

1 s, 3 s, 5 s, 10 s, 30 s, 60 
s, 3 min, 5 min, 10 min, 30 
min, 60 min, 3 hrs

H3JA-8C

Ex. H3JA-8A   100 to 120 VAC   1 s

Rated time

Supply voltage

Name/specifications

Models

Flush Mounting Adapter

Y92F-31

Mounting Track

50 cm (

&

) x 7.3 mm (t)

PFP-50N

1 m (

&

) x 7.3 mm (t)

PFP-100N

1 m (

&

) x 16 mm (t)

PFP-100N2

End Plate

PFP-M

Spacer

PFP-S

Track Mounting/
Front Connecting Socket

8-pin

PF085A

Back Connecting Socket

8-pin

US08

8-pin

P3G-08

8-pin, finger safe type

P3G-08 with Y92A-48G (see note 1)

Hold-down Clip (see note 2)

For PF085A Socket

Y92H-6

Summary of Contents for H3JA

Page 1: ...G 08 Socket 2 Hold down Clips are sold in sets of two RC Operation resetting system Time limit contact Mounting method Rated time Model Time limit operation self resetting SPDT Surface mounting flush mounting and DIN track mounting 1 s 3 s 5 s 10 s 30 s 60 s 3 min 5 min 10 min 30 min 60 min 3 hrs H3JA 8A DPDT 1 s 3 s 5 s 10 s 30 s 60 s 3 min 5 min 10 min 30 min 60 min 3 hrs H3JA 8C Ex H3JA 8A 100 ...

Page 2: ...20 or 200 to 240 VAC 50 60 Hz 24 VDC Operating voltage range 85 to 110 of rated supply voltage Power consumption H3JA 8A 100 to 120 VAC Approx 3 VA 1 3 W at 120 VAC 200 to 240 VAC Approx 5 VA 1 5 W at 240 VAC 24 VAC Approx 1 2 VA 0 9 W at 24 VAC 24 VDC Approx 0 8 W at 24 VDC H3JA 8C 100 to 120 VAC Approx 3 VA 1 1 W at 120 VAC 200 to 240 VAC Approx 5 VA 1 3 W at 240 VAC 24 VAC Approx 1 3 VA 1 W at ...

Page 3: ...uble amplitude in 3 directions for 10 minutes each Shock resistance Destruction 1 000 m s2 Malfunction 100 m s2 Ambient temperature Operating 10 C to 55 C Storage 25 C to 65 C Ambient humidity Operating 35 to 85 Life expectancy H3JA 8A Mechanical 10 000 000 operations min Electrical 60 000 operations min 7 A resistive load at 250 VAC 360 operations h H3JA 8C Mechanical 10 000 000 operations min El...

Page 4: ...oad 120 VAC inductive load cosf 0 4 30 VDC inductive load L R 7 ms 1 000 500 100 50 0 1 2 3 4 5 6 7 5 000 Switching operations x 10 3 f H3JA 8A H3JA 8C 100 ms min Rt Set time Set time Terminals 2 7 power 6 8 NO 5 8 NC Time UP indicator Orange Power ON indicator Green 100 ms min Rt Set time Set time Terminals 2 7 power 1 3 NO 6 8 1 4 5 8 NC Time UP indicator Orange Power ON indicator Green ...

Page 5: ...ecting socket Panel Cutout Recommended panel thickness 1 to 5 mm 44 46 40 37 4 11 22 91 3 13 15 5 US08 US08 Connecting Socket Track Mounting Front Connecting Socket PF085A Mounting Holes Terminal Arrangement Top View Mounting Height of Timer with Socket Note PF085A can be used as a front connecting socket Eight M3 5 7 sems Two 4 5 dia holes Two M4 or 4 5 dia holes H3JA Hold down Clips Set of Two C...

Page 6: ...minal Cover Conforming to VDE0106 P100 Y92A 48G Attachment for P3G 08 Socket Twelve 6 4 dia holes 34 47 7 x 47 7 48 x 48 47 4 16 5 24 6 27 6 Mounting Track PFP 100N PFP 50N PFP 100N2 4 5 15 25 25 25 25 10 10 7 3 0 15 35 0 3 27 0 15 1 4 5 15 25 25 25 25 15 10 10 35 0 3 27 24 16 29 2 1 1 5 1 000 500 see note 15 5 see note Note The values shown in parentheses are for the PFP 50N 1 000 ...

Page 7: ...7 H3JA H3JA Installation Terminal Arrangement End Plate PFP M Spacer PFP S 50 11 5 M4 x 8 pan head screw 10 6 2 1 8 1 35 5 35 3 1 8 1 3 4 8 5 16 12 44 3 34 8 16 5 10 H3JA 8A H3JA 8C ...

Page 8: ...ERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No L100 E1 1A OMRON Corporation Industrial Automation Company Measuring and Supervisory Controls Department Shiokoji Horikawa Shimogyo ku Kyoto 600 8530 Japan Tel 81 75 344 7108 Fax 81 75 344 7189 Printed in Japan 0401 2M 1100 A ...

Reviews: