background image

H5AN

Safety Precautions

Setting of Operating Time

Time Setting Range

Note:

The decimal point is not shown in the digital display.

1.

Since the H5AN Timer is capable of reading the input data at any 
time during normal operation, the set time can be changed during 
power application. This feature sets back the output from the 
timer by temporarily setting the longer time or quickens the output 
by setting the shorter time. During normal operation, the set time 
may be accidentally changed by touching a thumbwheel switch, 
causing the timer to operate with a different set time. To prevent 
this possibility, keep the front cover closed except when changing 
the set time.

2.

When the set time is all zeroes (e.g., 000.0 s or 00 hrs 00 min), 
there will be a momentary control output upon power application 
which can be used to check normal output. When changing the 
set time during normal operation, pay special attention not to alter 
the set value to this state.

3.

Since the sexagesimal system is adopted, when a rated time of 
99 min 59 s or 99 hrs 59 min is selected, any value set to 6 or 
more (i.e. 6-9) in the order of x 10 s or x 10 min respectively will 
be rated as 5. Some erroneous setting examples are shown 
below.

Examples of Setting/Actual Operating Time

4.

When changing the set time while power is being supplied, an 
inadequate push of the thumbwheel switches will display two 
numbers in one digital display window, causing the operating time 
to drift widely. Therefore, press the thumb-wheel switches surely. 
Take particular care in the case when the other three digits are all 
zero, since the improper setting of the fourth switch to create four 
zeroes will cause a momentary output.

5.

When operating the built-in selector switches of the H5AN-4DM 
Timer with a backup power supply function for memory 
protection, it is necessary to reset (either externally or manually) 
the timer at the time the power is applied.
Also when this type of timer is connected to a device (or 
manually) this must also be done when power is applied for the 
first time.

Note:

If the timer is not reset, it operates in accordance with the 
previous specifications or with the factory set specifications.

Rated time

Setting range

99.99 s

0.01 to 99.99 s (see note)

999.9 s

0.1 to 999.9 s (see note)

9999 s

1 to 9999 s

99 min 59 s

1 s to 99 min 59 s

999.9 min

0.1 to 999.9 min (see note)

99 hrs 59 min

1 min to 99 hrs 59 min

999.9 hrs

0.1 to 999.9 hrs (see note)

9999 hrs

1 to 9999 hrs

(Possible Operating Time)

(Undesirable Setting)

5 min 30 s

59 s
99 min

59 min
99 hrs

00 h 00 min 
(momentary 
output)

http://www.ia.omron.com/

10

(c)Copyright OMRON Corporation 2008   All Rights Reserved. 

Summary of Contents for H5AN Series

Page 1: ...N F C R K P and Q are available Ordering Information Note 1 Specify both the model number and supply voltage when ordering 2 The Timer is supplied with two mounting fixtures Operation system Resetting system No of digits Backup power supply function for memory protection Model Time limit operation integrating operation Power OFF resetting excluding M external resetting manual resetting automatic r...

Page 2: ... for externally connected components 12 VDC 10 80 mA permissible ripple 5 max Peak value Inrush current Time Measurement time Accuracy of operating time 0 01 0 05 s max power OFF start 0 005 0 03 s max reset start see note Setting error Influence of voltage Influence of temperature Insulation resistance 100 MΩ min at 500 VDC between current carrying terminal and exposed non current carrying metal ...

Page 3: ...00 operations can be expected The minimum applicable load is 10 mA at 5 VDC P reference value Switching operations 10 3 7 segment LED display Front cover Time up indicator Reset input indicator Pushbutton switch for manual reset Internal unit fixing screw One shot time adjustment screw Rated time label affixing section when a rated time label of 99 min 59 s is affixed http www ia omron com 3 c Cop...

Page 4: ...et value and then returns to all zeroes In DOWN mode the digital display continues to up 9999 and then decrements 9998 9997 after reaching all zeroes The control output is held until a reset input is applied C The digital display returns to the initial setting once the set time has elapsed and the timer restarts the timing operation When the set time has elapsed the output signal is generated duri...

Page 5: ...the one shot time The timer repeats this cycle P For the digital display the value at the up is held during the one shot time however the timing operation of the timer returns to the initial setting when the set time has elapsed and the timer restarts the timing operation When the set time has elapsed the output signal is generated during the one shot time The timer repeats this cycle Q In UP mode...

Page 6: ...e solid state output when the set time has elapsed etc Set these switches for programming the desired functional specifications by referring to Positions and Functions of Specification Selector Switches Open the front cover The internal unit comes out by loosening the internal unit fixing screw http www ia omron com 6 c Copyright OMRON Corporation 2008 All Rights Reserved ...

Page 7: ...etting range 0 99 99 s 0 01 to 99 99 s 1 999 9 s 0 1 to 999 9 s 2 9999 s 1 to 9999 s 3 99 min 59 s 1 s to 99 min 59 s 4 999 9 min 0 1 to 999 9 min 5 99 hrs 59 min 1 min to 99 hrs 59 min 6 999 9 hrs 0 1 to 999 9 hrs 7 9999 hrs 1 to 9999 hrs 8 99 99 s Same as switch position 0 9 999 9 s Same as switch position 1 Switch position Operating mode Display mode 0 N DOWN display 1 F 2 C 3 R 4 K 5 P Note Sa...

Page 8: ...V 12 V 12 V Contact output Unused Power supply For DC power Terminal 1 Terminal 2 Unused Internally connected Do not use unused terminals for relaying Leave them open Note Specifications for 12 to 24 VDC 48 VDC and 100 VDC models are listed separately in this datasheet External power supply AC Power Supply DC Power Supply Load 3 See note When a Load Operates with Contact Output When a Load Operate...

Page 9: ...e solid state circuit V should be 13 to 30 V and the VCE S of the transistor should be less than 3 V the current that flows from either terminal 9 or 10 is approximately 10 mA Moreover it is essential that the circuit be ON for gate or reset input and OFF when there is no input Connection of a Power Supply for Externally Connected Components The H5AN has a built in power supply for externally conn...

Page 10: ...of Setting Actual Operating Time 4 When changing the set time while power is being supplied an inadequate push of the thumbwheel switches will display two numbers in one digital display window causing the operating time to drift widely Therefore press the thumb wheel switches surely Take particular care in the case when the other three digits are all zero since the improper setting of the fourth s...

Page 11: ...iable within a range to 0 1 to 1 s Mounting A Mounting Fixture is included with the H5AN Mount the Unit using the Mounting Fixture so that the Unit is secure and does not move Purchase of H5AN No Yes Yes Yes No No Is the timer equipped with memory protection Drawn out the internal unit from the case or switch off the power to reset the timer Selection of specifications Was the timer reset after po...

Page 12: ...atteries are likely to explode if incinerated Label to cover holes Fixture Sunken nut Specifications label In the interest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 http www ia omron com 12 c Copyright OMRON Corporation 200...

Page 13: ...s subject to sulfidizing gas chloride gas or silicon gas The switching capacity for DC voltage loads is lower than that for AC voltage loads Timers with Non contact Outputs Short faults or open faults may occur due to destruction of the output element Do not use the Timer for a load that exceeds the rated output current Short faults or open faults may occur due to destruction of the output element...

Page 14: ...ot possible OMRON does provide special Timers with improved resistance to sulfidizing gas Ask your OMRON representative for details Power Supply Be sure that the voltage applied is within the specified range otherwise the internal elements of the Timer may be damaged Install a switch or circuit breaker that allows the operator to immediately turn OFF the power and label it to clearly indicate its ...

Page 15: ...s subject to sulfidizing gas chloride gas or silicon gas The switching capacity for DC voltage loads is lower than that for AC voltage loads Timers with Non contact Outputs Short faults or open faults may occur due to destruction of the output element Do not use the Timer for a load that exceeds the rated output current Short faults or open faults may occur due to destruction of the output element...

Page 16: ... may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this catalog Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems...

Reviews: