H5AN
Note: 1.
When a rated time of 99 min 59 s or 99 h 59 min is selected, the overflow values of the digital display when using the DOWN (countdown)
function will be indicated as 9959, 9958, 9957, ... in modes F, K, and Q.
2.
In this timing chart, the number of step advances during the one-shot time varies in accordance with the selected rated time and duration
of the one-shot time.
3.
In C and P modes, set time value n should be sufficiently longer than the one-shot time t.
K
In UP mode, the digital display
continues to increment up to “9999”,
even after reaching the set value and
then returns to all zeroes. In DOWN
mode, the digital display continues up
to 9999, and the decrements “9998,
9997, ...,” after reaching all zeroes.
The timer restarts the timing operation
when the incrementing or
decrementing value reaches the set
value.
The output is generated during the
one-shot time. The timer repeats this
cycle.
P
For the digital display, the value at the
up is held during the one-shot time;
however, the timing operation of the
timer returns to the initial setting when
the set time has elapsed and the timer
restarts the timing operation. When
the set time has elapsed, the output
signal is generated during the one-
shot time. The timer repeats this cycle.
Q
In UP mode, the digital display
continues to increment after reaching
the set value during the one-shot time.
In DOWN mode, the digital display
continues to 9999 and then
decrements “9998, 9997, ...,” after
reaching all zeros during the one-shot
time. However, in both UP and DOWN
modes, the digital display returns to
the initial setting after the one-shot
time and the timer restarts the timing
operation. When the set time has
elapsed, the output signal is
generated during the one-shot time.
The timer repeats this cycle.
Mode
UP display
DOWN display
Operation after the set time is up
http://www.ia.omron.com/
5