H5BR
H5BR
4
Nomenclature
15
14
16
17
10
8
1
2
4
6
3
5
7
11
9
13
12
1. Power indicator
2. Signal input indicator
3. Reset indicator
4. Gate indicator
5. Key protection indicator
6. Control output indicator
7. Batch output indicator
8. Present value
(character height: 12mm) (Non
significant zeroes suppressed)
9. Set value
(character height: 8 mm)
(Indicates value in set function mode)
10. Mode indicator
11. Timing indicator
12. Elapsed time indicator
(Indicates the fraction of a unit which
has elapsed. Displayed for timing
ranges of 999.9 min. or greater.)
Display
13. Increment keys (1 to 4)
(Used to change the
corresponding digit of the set
value. Used to change data in the
setting mode.)
14. Display key
(Switches to the present value
display.)
Operation key
15. Batch key
(Switches to the batch display.)
16. Mode key
(Switches from run mode to
setting mode. Changes items in
the setting mode.
17. Reset key
(Resets timing and outputs.)
Factory Settings
The following table shows the timer settings when it is shipped. Please change the settings as necessary to suit the system before operation.
Settings and the display receive power from the internal battery and are therefore unaffected by external power interruptions.
Model
H5BR-B (Standard)
Time range
- -. - -s
Present value
0.00 s
Presets
0.00 s
Batch present count
0
Batch setting count
0
UP/DOWN mode
UP
Output mode
A: Signal on delay (I)
Output time
Hold
Input signal time
20 ms
Key protect level
KP-1
Note:
With the initial settings, there will be no output even if the power supply is connected. External inputs and outputs cannot be used
without a power supply.