Mode
Setting item
Applicable model
Description
Setting procedure
H7BR-B
H7BR-C
Set mode
Compensa-
No
Yes
The present value is
Change the value of the digits with the correspond-
(cont'd.)
tion count
changed to the set
ing keys, 1 to 6.
value
value on receipt of the
compensation input.
The +/- key changes the set value mark.
Key protec-
Yes
Yes
Blocks certain keys to
Sequence when changing the key protection
tion level
prevent accidental opera-
level using the increment keys (1 to 6).
tion. The key protection
level, kP-1 to kP-4, deter-
mines which keys are
locked when the key
protection input is ON.
The locked keys are
crossed out in the dia-
gram on the right.
Teaching
Prescale
No
Yes
—
Press TEACH key to set prescale value
mode
value
automatically.
Set value 1
No
Yes
—
Press TEACH key to set present value as
(double pre-
the set value.
set model
only)
Set value 2
No
Yes
Note:
1. Changes made in set mode become effective when run mode is entered.
2. The control output is inhibited in the teaching mode.
3. The TEACH key and the teaching function do not operate during power interruptions, but other functions are not affected.
<KP-1>
<KP-2>
<KP-3>
<KP-4>
H7BR-C
TEACH
H7BR-C
TEACH
H7BR-C
TEACH
H7BR-C
TEACH
■
EXAMPLES
Run Mode
Changing the Set Value
1. Press the DISPLAY key to change the displayed preset
value 1 and 2 during operation
2. Change the set value from 250 to 1,250.
• Press keys 1 through 6 to increment the corresponding
column by 1.
• Nonsignificant zeros are normally not shown on the set
value display.