H7CR

H7CR

23

Item

Applicable Counters

Description

Setting values

Input mode

H7CR-A, H7CR-SA

Determines the input mode:

Increment keys 1 to 6 change the display.

(default)

H7CR-B, H7CR-SB

Up, Down, Reversible A, Reversible B,

H7CR-C, H7CR-SC

Reversible C

H7CR-8, H7CR-11

Press the Up key until the desired
mode is displayed.

*There is no Up or Down mode for H7CR-C
  and H7CR-SC (+/– range) counters.

Output mode

H7CR-A, H7CR-SA

Determines the operation of the

Increment keys 1 to 6 change output mode.

and OUT 2

H7CR-B, H7CR-SB

control outputs. Refer to "Output

output time

H7CR-C, H7CR-SC

Operations" tables for details. Also

H7CR-8, H7CR-11

determines the output time for control
output (OUT2) in single preset
counters.

OUT 1

H7CR-B, H7CR-SB

Designates the output time for

Increment keys 1 to 6 change output time.

output time

H7CR-C, H7CR-SC

output 1 (double preset models only).

(double preset models only)

Press the increment keys to set the
desired time for output 1.

*Hold mode is available only on H7CR-BW
  and H7CR-SBW counters.

(Applicable to output modes C, R, K, P, Q,
and A only.)

Counting speed

H7CR-A, H7CR-SA

Changes the input filter for counting

Increment keys 1 to 6 change count speed.

H7CR-B, H7CR-SB

inputs. Used to prevent counting

H7CR-C, H7CR-SC

errors caused by input interference.

H7CR-8, H7CR-11

Press the increment keys to set the
desired speed. A "k" on the display
indicates kilocycles (1000 cycles).

Minimum reset

H7CR-B, H7CR-SB

Determines the minimum time

Increment keys 1 to 6 change reset time.

times

H7CR-C, H7CR-SC

required for the reset input.

H7CR-8, H7CR-11

Press any increment key to switch
between 1 and 20 ms.

Item

Applicable Counters

Description

Setting values

Preset 1, H7CR-B, H7CR-SB

Determine the timing of the outputs in comparison to

Sequence when changing a digit

Preset 2 H7CR-C, H7CR-SC

the present count value according to the output mode.

using the increment keys (1 to 6).

set value

The DISPLAY key switches between set value 1 and 2 in
double preset models. Use the increment keys (1 to 6)
to change a digit.

Minus sign displayed for leftmost
digit of H7CR-C and H7CR-SC
(+/– range counters) by using
increment key 6.

  SUMMARY OF SETTING PROCEDURES

Run Mode

Settings and operation are easily achieved as shown below. The settings that are possible for each model vary. After changing modes,
the counter is ready to accept setting changes to default items.

Setting Mode

Up    Down  Reversible A  Reversible B  Reversible C

Note:  Settings changed in the Setting mode are effective only after returning to the Run mode.

1 ms

20 ms

Summary of Contents for H7CR-11

Page 1: ...for positioning and production control Easy to read backlit LCD display On line change of set value 4 level key protect H7CR S short 64 mm 2 52 in body Number of presets One Display type 6 digit LCD n...

Page 2: ...SORIES 12 VDC sensor supply voltage 24 VDC sensor supply voltage Description Part number Sockets 11 pin Bottom surface or track mounting top screw terminals P2CF 11 Bottom surface or track mounting to...

Page 3: ...r 9 999 0 001 to 99 999 Decimal point None Rightmost 3 digits adjustments Sensor power None 12 or 24 VDC model specific supply Input signals Count reset Count reset key protect Input method No voltage...

Page 4: ...ng to C R and Q operation operation P and Q operation resets resets resets Scaling function None 0 001 to 99 999 for 6 digit 0 001 to 9 999 for 4 digit Decimal point None Rightmost 3 digits adjustment...

Page 5: ...ermissible ripple 20 max permissible ripple 20 max Operating voltage range 85 to 110 of rated voltage Power consumption Approx 1 7 VA at 50 Hz Approx 6 6 VA at 50 Hz 240 VAC 3 2 W at 24 VDC 240 VAC 0...

Page 6: ...et 20 ms 1 or 20 ms 1 or 20 ms power reset 0 5 s Key protect Not applicable Response time 1 second One shot durations 10 50 100 200 10 50 100 200 and 500 ms 10 50 100 200 and 500 ms and 500 ms separat...

Page 7: ...or phase difference inputs accepted Maximum counting speed 5 kcps Reset Present value reset to zero in Up or Up Down modes to preset with 1 stage models in Down mode and to preset 2 for 2 stage models...

Page 8: ...e Down decrement mode Up Down A Command input mode Up Down B individual input mode H L CP2 Count H L CP1 0 1 2 3 2 1 2 3 A A H L CP2 Count H L CP1 0 1 2 3 2 1 1 2 3 2 H L H L 0 1 2 3 1 2 3 BB B B Coun...

Page 9: ...and goes OFF after expiration of the one shot period for Output 2 One shot time periods for Output 1 and 2 are independent Up Down Reversible A B and C One shot output from Output 1 Sustained output...

Page 10: ...stained output Up Down Reversible A B and C Output Mode K Present value runs continuously Output 1 latches ON at preset 1 and goes OFF after expiration of the one shot period for Output 2 One shot tim...

Page 11: ...ed output One shot outputs can be set to 10 50 100 200 or 500 ms One shot output from Output 2 Sustained output Output Mode Q Present value runs continuously through one shot time period and returns t...

Page 12: ...ge Output 1 goes ON for one shot whenever present value is equal to preset 1 Output 2 goes ON for one shot whenever present value is equal to preset 2 Output Mode D Present value increments and decrem...

Page 13: ...output One shot output Sustained output level input One shot outputs can be set to 10 50 100 200 or 500 ms Notes Counting inputs are not acknowledged while the reset input is ON The compensation inpu...

Page 14: ...ax 1 97 Eight M3 5 x 7 5 sems 3 0 12 4 5 0 18 20 3 max 0 80 Two 4 5 dia or two M4 socket mounting holes Surface Mounting Holes 4 0 16 Terminal Arrangement Internal Connections Top View 40 0 2 1 57 70...

Page 15: ...o 4 5 dia holes 4 0 16 3 0 12 4 5 0 18 35 4 1 39 31 2 max 1 23 Two 4 5 dia or two M4 socket mounting holes Surface Mounting Holes 40 0 2 1 57 50 max 1 97 P3GA 11 Back Connecting Socket Terminal arrang...

Page 16: ...dels 50 5 1 99 47 2 1 86 47 2 1 86 50 5 1 99 Y92A 48G Finger Safe Terminal for P3G A Conforming to VDE0106 P100 Twelve 6 4 dia holes 34 47 7 x 4 47 48 x 48 16 5 47 4 27 6 PFP 100N PFP 50N Mounting Tra...

Page 17: ...n the two retaining screws To release the adapter lift the tab at the rear of the adapter Several counters may be mounted close together using Y92F 30 adapter as shown here When mounting two or more c...

Page 18: ...nclude the following H7CR BW H7CR BWG H7CR B4W H7CR BWV H7CR BWVG H7CR B4WG H7CR CW H7CR CWG H7CR CWV H7CR CWVG 12 or 24 VDC sensor power supply 12 or 24 VDC sensor power supply Key protect CP1 input...

Page 19: ...CR CVSG Applicable models include the following H7CR BWS H7CR BWSG H7CR SBWSL H7CR BWVS H7CR BWVSG H7CR SCWSL H7CR CWS H7CR CWSG H7CR CWVS H7CR CWVSG Single Preset H7CR 8 H7CR 84 H7CR 8S Single Preset...

Page 20: ...output sensor powered by built in DC power source Counter Sensor CP1 CP2 reset etc Input use 0 V 12 or 24 VDC V 30 V max 0 V Contact Input Switch contact Counter CP1 CP2 reset etc Input use 0 V Solid...

Page 21: ...value 8 Display key switches to the setting displays For double preset counters it switches between set values 1 and 2 9 Mode key switches from run mode to function setting mode Changes items in the f...

Page 22: ...any settings before operating the counter Settings and display are possible with or without power supplied although power supply is required for inputs and outputs to operate Model H7CR A Economy type...

Page 23: ...nt speed H7CR B H7CR SB inputs Used to prevent counting H7CR C H7CR SC errors caused by input interference H7CR 8 H7CR 11 Press the increment keys to set the desired speed A k on the display indicates...

Page 24: ...re effective only after returning to the Run mode Changing the Set Value When changing the set value while the counter is operating an output will be produced if the set value ever equals the present...

Page 25: ...RESET key or a reset input 2 Press the MODE key to scroll successively through the items that can be set Release the MODE key to select the desired item 3 Changing the counting speed or another selec...

Page 26: ...ficient to start the counter due to the switching regulator contained in the counter s internal circuitry Connect the power supply voltage through a relay or switch in such a way that the voltage reac...

Page 27: ...p value is on hold Mode A can be used for a start signal for sequence control equipment Mode F Go to Mode F to monitor the number of overrun objects The process value is displayed normally It is possi...

Page 28: ...gh Ontario M1B 5V8 1 800 55 OMRON 416 286 6465 Cat No GC TMCN1 3 02 Specifications subject to change without notice Printed in the U S A OMRON ON LINE Global http www omron com USA http www omron com...

Reviews: