9
H7CR
H7CR
Up
Down
Reversible A, B, and C
Output Mode F Present value runs continuously. Outputs are maintained until reset.
Output Mode N Present value display and outputs are maintained until reset.
Up
Down
Reversible A, B, and C
Output Mode C Present value is placed in reset start status as soon as preset count is reached; the preset is not actually displayed.
Outputs are one-shot and operate repeatedly. Output 1 is latches ON, and goes OFF after expiration of the one-shot period for Output
2. One-shot time periods for Output 1 and 2 are independent.
Up
Down
Reversible A, B, and C
One-shot output from Output 1
Sustained output
One-shot outputs can be set to 10, 50, 100, 200 or 500 ms.
One-shot output from Output 2
Sustained output
Bold line represents present value; Output 2 operation applies for single-preset models. H7CR-A models have only Mode N and F.
Reset
999,999
Output 2
Output 1
0
Preset 1
Preset 2
999,999
Output 1
0
Preset 1
Preset 2
Output 2
Reset
■
H7CR-A AND H7CR-B COUNTER OUTPUT OPERATIONS
Preset 2
Preset 1
Output 1
Output 2
0
999999
Reset