31
H7CX
H7CX
Operation in Configuration Selection Mode
Select which H7CX configuration is used (i.e., 1-stage counter, 2-stage counter, total and preset counter, batch counter, dual counter, or
tachometer) in configuration selection mode. The H7CX is also equipped with a DIP switch monitor function, a convenient function that
enables the settings of the DIP switch pins to be confirmed using the front display.
1
+
1
OFF
ON
2
3
4
5
6
7
8
1
1
The status of the DIP switch pins (1 to 8) can be confirmed using the
keys.
Note:
This display is possible only if DIP switch pin 1 (DIP switch set-
tings) is set to ON (i.e., enabled).
Select the configuration using the keys. ( key only for 6-
digit models)
The H7CX is factory-set to the 1-stage counter configuration (2-stage
counter configuration with H7CX-AW
@
/-A4W
@
models).
To change the mode to configuration selection mode, press
the Key for 1 s min. with the key held down. The
mode will not change if the key is pressed first.
MODE
1
Power ON
Configuration
selection
Ru
n
M
o
d
e
Co
nf
igu
ra
tion
S
e
le
c
tio
n M
ode
DIP switch
monitor
Note:
1. When the mode is changed to configuration selection mode, the present value is reset, outputs turns OFF, and counting
(measuring) stops.
2. Setting changes made in configuration selection mode are enabled when the mode is changed to run mode. If the con-
figuration is changed, the set value (or set value 1 and set value 2), OUT1 set value or OUT2 set value are initialized.
Indicates that DIP switch pin 8 is ON.
Indicates that DIP switch pin 7 is OFF.
Indicates that DIP switch pin 6 is ON.
Indicates that DIP switch pin 5 is OFF.
Indicates that DIP switch pin 4 is ON.
Indicates that DIP switch pin 3 is OFF.
Indicates that DIP switch pin 2 is ON.
Indicates that DIP switch pin 1 is ON.
Example
1 s min.
The configuration that can be selected depend on the model.
(1-stage counter) (2-stage counter)
(Dual counter)
(Total and
preset counter)
(Batch counter)
(Tachometer)
1
Counting stopped
Counting possible
(See note 2.)
(See note 1.)