SAFETY INFORMATION

To assure the correct use of the product, basic safety measures should always be followed including the 
warnings and cautions listed in this instruction manual.

OPERATING THE DEVICE

Do not use this monitor if you have a cardiac pacemaker or other implanted medical device. The Full Body 
Sensor Body Composition Monitor and Scale passes an extremely weak electrical current of 50kHz and less 
than 500µA through your body when taking a measurement to determine the amount of fat tissue. This weak 
current is not felt while using the monitor. Do not use, or allow others to use, this monitor if fitted with a 
cardiac pacemaker or other medical device.

Pregnant women should not use this device.

Contact your physician or healthcare provider before beginning a weight reduction or exercise program.

Keep the monitor out of the reach of young children. The cord can become entangled and cause strangulation.

Persons with disabilities or persons who are physically frail should be assisted by another person when using 
this monitor or use a handrail, a walker, or other support device to prevent falling when stepping on and off the 
monitor.

Read all of the information in the instruction manual and any other literature in the box before operating the 
unit.

Do not use mobile telephones, microwave ovens or other devices that generate strong electrical or 
electromagnetic fields near the monitor. This may result in an operational failure.

Do not step on the edge or the display area of the measurement platform. The monitor may tilt. The display unit 
may be damaged.

Do not step on the measurement platform when your body or feet are wet, for example after taking a bath or 
shower. You may slide and lose your balance.

Do not place the monitor on a cushioned floor surface such as a carpet or mat. A correct measurement may not 
be possible.

Do not use the unit on slippery surfaces such as tile floors or wet floors. The monitor may move. You may lose 
your balance and fall.

Do not jump on the measurement platform. You may lose your balance and fall. The monitor may be damaged.

Stand on the measurement platform with bare feet. Attempting to stand on the measurement platform when 
wearing socks may cause you to slip and lose your balance.

Do not insert the batteries with their polarities incorrectly aligned.

SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL

Warning

Indicates a potentially hazardous situation which, if not avoided, could result 
in death or serious injury.

Caution

Indicates a potentially hazardous situation which, if not avoided, may result 
in minor or moderate injury to the user or patient or damage to the equipment 
or other property.

Summary of Contents for HBF-510

Page 1: ...Instruction Manual Full Body Sensor Body Composition Monitor and Scale Model HBF 510...

Page 2: ...erm Planning for Successful Weight Loss 10 Recommended Measurement Times 11 Operating Instructions Know Your Unit 13 Battery Installation 16 Setting Personal Data 18 Changing Personal Data 20 Deleting...

Page 3: ...ower switch on select your Personal Profile Number and step onto the measurement platform Your HBF 510 comes with the following components Monitor Scale Instruction Manual 4 AA Batteries Measurement L...

Page 4: ...ure in the box before operating the unit Do not use mobile telephones microwave ovens or other devices that generate strong electrical or electromagnetic fields near the monitor This may result in an...

Page 5: ...tion Operate the unit only as intended Do not use for any other purpose This unit is intended for home use only It is not intended for professional use in hospitals or other medical facilities This un...

Page 6: ...ethod Muscles blood bones and body tissues with high water content conduct electricity easily On the other hand body fat does not store much water therefore has little electric conductivity The Omron...

Page 7: ...hich is stocked for energy during physical activity While too much body fat may be unhealthy having too little fat can be just as unhealthy Also the distribution of body fat in men and women is differ...

Page 8: ...s of fat in the bloodstream which may lead to conditions such as high cholesterol heart disease and type 2 diabetes In order to prevent or improve these conditions it is important to try to reduce the...

Page 9: ...equirements The more muscle you have the more calories your body will burn Building skeletal muscle can help prevent rebound weight gain The maintenance and increase of skeletal muscle is closely link...

Page 10: ...scle can prevent rebound weight gain The Omron Full Body Sensor Body Composition Monitor and Scale tracks your progress by monitoring weight skeletal muscle body fat and BMI to help you reach your goa...

Page 11: ...ts Under the Following Conditions Immediately after vigorous exercise after a bath or sauna After drinking alcohol or a large amount of water after a meal about 2 hours If a measurement is taken under...

Page 12: ...be related to changing ratios of body fluid and or body composition The body fat percentage measured by this monitor may significantly differ from the actual body fat percentage for the following peop...

Page 13: ...Front View Grip Electrodes Grip Electrodes Display UP Button DOWN Button SET MODE Button Display Unit Holder Cord Foot Electrodes Heel Electrode Foot Electrodes Heel Electrode Power Switch Components...

Page 14: ...r Weight Results Body Composition Results Measurement Progress Body Fat Percentage Skeletal Muscle Percentage Visceral Fat Level and BMI Classification Bar Guest Indicator Personal Profile Number Disp...

Page 15: ...ck into place POWER SWITCH The power switch is located at the front of the monitor Press the power switch to turn the monitor on and off The power will automatically switch off in the following condit...

Page 16: ...eries so the positive and negative polarities match the polarities of the battery compartment as indicated in the battery compartment For both the top row and the bottom row slide the first battery in...

Page 17: ...eries supplied with the unit may have a shorter life Remove the batteries if you do not intend to use the unit for a period of three months or longer before placing in storage CAUTION Should battery f...

Page 18: ...lay then the display changes to 0 0 lb Wait until 0 0 lb appears on the display 2 Lift the Display Unit out of the Display Unit Holder NOTE This monitor can be set to either the US or Metric System Pe...

Page 19: ...the number and the symbols for gender age and height blink on the display If the personal data has been entered for the number the Personal Profile Number blinks on the display B Guest mode Press the...

Page 20: ...e gender and height appear in this sequence on the display The 0 0 lb symbol appears on the display You can now take a measurement using the Personal Profile Number you selected or the Guest mode Refe...

Page 21: ...display changes to 0 0 lb Wait until 0 0 lb appears on the display 2 Select the Personal Profile Number you want to delete 1 Press the USER button to select your personal profile number 1 through 4 T...

Page 22: ...your arms horizontally and extend your elbows straight to form a 90 angle to your body Stand with your knees and back straight and look straight ahead Hold the display unit in front of you Make sure...

Page 23: ...the DOWN button pressed until lb and kg blink on the display 2 Press the DOWN button to select the mode lb or kg This will automatically change cm and feet inch under height setting 3 Press the SET M...

Page 24: ...e Number selected will blink once NOTE If the following appears on the display no personal data was entered for the number you selected Refer to SETTING PERSONAL DATA on pages 19 and 20 B Guest mode 1...

Page 25: ...ars on the display extend your arms straight at a 90 angle to your body 3 When the measurement is completed your weight is displayed again Step off the measurement platform The display will show your...

Page 26: ...is 18 to 80 years old The age range for the body fat percentage classification is 20 to 79 years old 6 Press the Power Switch to turn the monitor off Store the Display Unit in the Display Unit Holder...

Page 27: ...ender Age Low Normal 0 High Very High Female 18 39 24 3 24 3 30 3 30 4 35 3 35 4 40 59 24 1 24 1 30 1 30 2 35 1 35 2 60 80 23 9 23 9 29 9 30 0 34 9 35 0 Male 18 39 33 3 33 3 39 3 39 4 44 0 44 1 40 59...

Page 28: ...Metric mode 1 Keep the DOWN button pressed until lb and kg blink on the display 2 Press the DOWN button to select the desired measurement unit lb or kg This will automatically change cm and feet inch...

Page 29: ...Body Composition values are outside the measurement range Check the settings entered for your personal data Change the settings if needed Retake the measurement The main unit cannot measure body compo...

Page 30: ...ur worn batteries The weight value is displayed abnormally low or high Place the monitor on a hard and level floor The Body Composition value is displayed abnormally low or high Refer to RECOMMENDED M...

Page 31: ...oring Remove the batteries if the monitor will not be used for three months or longer Store the Display Unit in the Main Unit as shown in the figure As you place the lower portion of the Display Unit...

Page 32: ...one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit different...

Page 33: ...of Purchase Include a letter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Because of possible loss in transit we...

Page 34: ...lassification 0 Normal High Very High with 9 levels of Bar display The age range for the skeletal muscle percentage and visceral fat level is 18 to 80 years old The age range for the body fat percenta...

Page 35: ...35 NOTES...