3-3
Battery Installation Procedure
WARNING
• At least 3 people are required to lift the battery.
• You must wear proper Personal Protective Equipment (PPE) for removing, instal-
ling, and lifting the battery or when working around a leaking battery.
WARNING
Always use safe lifting practices when removing or installing the battery.
Precautions for Safe Use
Only use chargers and batteries supplied by OMRON. The charger shall only be used to charge
an HD-1500 AMR battery.
Precautions for Correct Use
During the initial AMR installation and configuration, install a fully-charged battery.
Follow these steps to install a battery.
1
Remove the AMR front skin to access the battery compartment.
Refer to
6-9-1 Removing and Replacing Skins
on page 6-18 for more information.
2
Unlatch and open the battery door. The battery door pivots downward and rests on the floor.
This allows you to use the battery door as a ramp.
3
Use the extended handle to push the battery into the AMR.
As the battery gets pushed in, the power connector installed on top of the battery case makes
a blind-mate connection with the power connector attached to the chassis.
4
Collapse the handle before pushing the battery all the way into the AMR.
Release the locking collars and then slide the handle into the battery.
3 Installation
3-9
HD-1500 Platform User's Manual (I645)
3-3 Battery Installation Procedure
3
Summary of Contents for HD-1500 Platform
Page 1: ...HD 1500 Platform User s Manual I645 E 03 ...
Page 6: ...Manual Information 4 HD 1500 Platform User s Manual I645 ...
Page 38: ...Revision History 36 HD 1500 Platform User s Manual I645 ...
Page 206: ...5 Troubleshooting 5 14 HD 1500 Platform User s Manual I645 ...
Page 236: ...6 Maintenance 6 30 HD 1500 Platform User s Manual I645 ...
Page 250: ...Appendices A 14 HD 1500 Platform User s Manual I645 ...
Page 251: ...I Index I 1 HD 1500 Platform User s Manual I645 I ...
Page 254: ...Index I 4 HD 1500 Platform User s Manual I645 ...
Page 255: ......