USER PWR
The USER PWR connector on the User Access Panel provides unregulated battery power for payload
structure devices. Use the information below to understand all USER PWR connections.
Additional Information
Refer to
on page 2-18 for connector type and specifications.
0 VDC
48 to 56 VDC
REG PWR
The REG PWR connector on the User Access Panel provides regulated 24 VDC power and is typically
used for payload structure control devices. Use the information below to understand all REG PWR
connections.
Additional Information
Refer to
on page 2-18 for connector type and specifications.
3 Installation