6-6
Inspection Intervals
Perform inspections of the following safety and warning devices for proper function.
Item
Inspection
Frequency
Additional Information
Signal Beacons
(optional)
Weekly
Check for proper operation of any optional signal beacons. Refer to
6-5 Drive Power Indicator Check Procedure
mation.
Light Discs
Weekly
Check for proper operation of the light discs. Make sure all segments and
colors are functioning properly.
Light Strips
Weekly
Check for proper operation of the light strips. Make sure all segments and
colors are functioning properly.
Buzzer
Weekly
Check the audible buzzer for proper operation.
Speakers
As needed
Check the speakers for proper operation (if used).
E-STOP Buttons
Weekly
Check for proper operation of the E-STOP buttons. Refer to
on page 3-36 for more information.
Safety Laser Scan-
ners
Weekly
Check for proper operation of the Safety Laser Scanners. Refer to
on page 3-36 for more information.
Mechanical Brakes
Annually
Check for proper operation of the mechanical brakes. Refer to
chanical Brake Inspection Procedure
on page 6-9 for more information.
Caster, Drive
Wheel, and Drive
Assembly
3 months
Contact your OMRON representative.
Caster and Drive
Wheel Treads
3 months
Contact your OMRON representative.
Caster Swivels
3 months
Check the caster swivels and tighten if loose.
AMR Charging
Contacts
3 months
Check the AMR charging contacts for wear or debris. Refer to
on page 6-10 for more information.
Docking Target
Charging Contact
Assembly
3 months
Inspect the Docking Target Charging Contact assembly. Refer to
6-6-3 Docking Target Charging Contacts Inspection
on page 6-10 for
more information.
Labels
Weekly
Verify all labels are present, legible, and undamaged.
Batteries (in-use
and stored)
Six months
Check the battery for charge state, leaks, or damage. Refer to
on page 6-13 for more information.
Check safety and
warning labels
Weekly
Refer to
6-6-4 Safety and Warning Labels
mation.
6-6-1
Mechanical Brake Inspection Procedure
Perform annual inspection of the mechanical brakes for proper operation. Before you begin, make
sure it is safe to manually move the AMR to an open area with level floor.
Use the following procedure to verify that the mechanical brakes engage and disengage properly.
This procedure does not require a Lock-out Tag-out procedure in advance.
1
Connect the pendant to the AMR and drive forward approximately 2 m in order to align the cas-
ters in the direction of motion.
2
Release the three-position enabling device to ensure that the AMR is in protective stop mode.
6 Maintenance
6-9
HD-1500 Platform User's Manual (I645)
6-6
Inspection Intervals
6
6-6-1
Mechanical Brake Inspection Procedure
Summary of Contents for HD-1500 Platform
Page 1: ...HD 1500 Platform User s Manual I645 E 03 ...
Page 6: ...Manual Information 4 HD 1500 Platform User s Manual I645 ...
Page 38: ...Revision History 36 HD 1500 Platform User s Manual I645 ...
Page 206: ...5 Troubleshooting 5 14 HD 1500 Platform User s Manual I645 ...
Page 236: ...6 Maintenance 6 30 HD 1500 Platform User s Manual I645 ...
Page 250: ...Appendices A 14 HD 1500 Platform User s Manual I645 ...
Page 251: ...I Index I 1 HD 1500 Platform User s Manual I645 I ...
Page 254: ...Index I 4 HD 1500 Platform User s Manual I645 ...
Page 255: ......