CAUTION
An AMR must have a readily visible warning device such as a user-supplied flashing
light, to indicate when it is either ready to move or is moving.
When using large or complex payload structures, you may need to install additional user-supplied sig-
nal beacons to ensure visibility of the AMR. The exact implementation of this signal beacon(s) de-
pends on the design of your payload or payload structure. Make sure that the signal beacon(s) re-
mains visible under all operating conditions, and from all sides so that people can always see it. Con-
sider the design of your payload structure for high visibility, including when the AMR is transporting
objects.
An additional signal beacon is not included with the AMR. You can optionally supply and install such a
device if required. To comply with relevant standards, the sequence of the lights from top down must
be red, yellow, and green.
A signal beacon may also be used to indicate movement and to signal that the AMR requires some
interaction. Refer to
3-5-2 User Access Panel Connections
on page 3-15 for more information.
1-6-4
Additional Warning Buzzers
The AMR Controller provides an output for controlling an additional warning buzzer as an auditory
warning device. The warning buzzer is connected to the Safety Controller.
The buzzer must be audible above the ambient noise of the environment that the AMR operates in.
Depending on your environment's noise level, you may need to add an additional buzzer installed on
your payload structure so that the buzzer can be heard over the ambient noise level. It is the end-us-
er's responsibility to verify this requirement.
The LIGHTS port in the User Access Panel can support a user-supplied warning buzzer. You can in-
stall it in either the AMR or in a location of your choice in your payload structure. Refer to
on page 3-15 for more information.
Additional Information
You can optionally supply an LED signal tower which includes a built-in warning buzzer, or a
dedicated warning buzzer. Contact your OMRON representative for more information on the
available options.
1-6-5
Side Lasers
Side Lasers are optional, factory-installed sensors used to detect obstacles that protrude into the
AMR's path, but may not be detected by the Safety Laser Scanners or Low Lasers. These are re-
quired when the payload structure is tall and there is an increased risk of collisions not detected by the
Safety Laser Scanners. These optional sensors are oriented so that they scan in a vertical plane, off-
set 90 degrees from Safety Laser Scanners and Low Lasers.
Side Lasers can be relocated to the payload structure to prevent the structure from interfering with the
scanning plane. Mount the Side Lasers in such a way that they protrude enough so that the payload
does not interfere with the scanning plane. You must determine the mounting method for the optional
Side Lasers when placing them on a payload structure. Refer to
3-8 Side Laser Relocation to the Pay-
on page 3-27 for more information.
1 Overview
1-23
HD-1500 Platform User's Manual (I645)
1-6 Optional Items
1
1-6-4
Additional W
arning Buzzers
Summary of Contents for HD-1500 Platform
Page 1: ...HD 1500 Platform User s Manual I645 E 03 ...
Page 6: ...Manual Information 4 HD 1500 Platform User s Manual I645 ...
Page 38: ...Revision History 36 HD 1500 Platform User s Manual I645 ...
Page 206: ...5 Troubleshooting 5 14 HD 1500 Platform User s Manual I645 ...
Page 236: ...6 Maintenance 6 30 HD 1500 Platform User s Manual I645 ...
Page 250: ...Appendices A 14 HD 1500 Platform User s Manual I645 ...
Page 251: ...I Index I 1 HD 1500 Platform User s Manual I645 I ...
Page 254: ...Index I 4 HD 1500 Platform User s Manual I645 ...
Page 255: ......