Precautions for Safe Use
If the supplied Front Panel is not used, a High Power indicator light must be present in the sys-
tem. This indicator light must be amber in color. It must be either mounted to the robot or inte-
grated into the work cell where it is visible from all approaches or entry points.
Precautions for Correct Use
• Either a Front Panel or equivalent circuits are required to enable High Power to the robot. Re-
on page 3-38 for more information.
• If the Front Panel High Power ON / OFF indicator fails, you might incorrectly assume that
High Power is OFF, and the robot is safe. To prevent this, a failed indicator causes an error
(-924) *Front panel HIGH POWER lamp failure* and locks out the High Power enabling until
you replace the indicator. Refer to the
V+ User's Manual (Cat. No. I671)
for more information
about error handling. Refer to
High Power Indicator Check Procedure
mation about High Power indicator operation verification.
Additional Information
• The Front Panel is supplied with an extension cable that must be used to connect it to the
XFP connector on the XSYSTEM cable. Refer to
3-8-1 Installing the Front Panel
• Design of the factory-supplied Front Panel E-Stop is in accordance with the requirements of
IEC 60204-1 and ISO 13849.
WARNING
• If you supply your own Front Panel, its design must comply with the requirements of
IEC 60204-1 and ISO 13849. The E-Stop's push button must comply with ISO
13850 (Clause 5.5.2).
• If an operator is going to be in the work cell with the switch in Manual mode, the
operator must carry an enabling device such as the T20 pendant.
• Whenever possible, perform Manual mode operations with all personnel outside the
workspace.
• Disabling the High Power button violates IEC 60204-1. Do not alter its functionality.
• In Automatic mode, the robot can move unexpectedly. Ensure all personnel remain
clear of the cell when Automatic mode is enabled.
Control Power
LED Indicator
Mode Selection
Switch
High Power
Enable Button
Emergency
Stop Button
High Power
Indicator
Use the information in the table below to understand Front Panel item details.
Item
Description
Control Power LED Indicator
Provides an indication that the robot is receiving 24 VDC Control Power
with a green LED.
1 Overview
1-7
i4L Robots with EtherCAT User's Manual (I659)
1-2
Robot Features
1
1-2-3
Front Panel
Summary of Contents for i4-350L
Page 1: ...i4L Robots with EtherCAT User s Manual i4 350L i4 450L i4 550L I659 E 01...
Page 6: ...Manual Information 4 i4L Robots with EtherCAT User s Manual I659...
Page 54: ...1 Overview 1 26 i4L Robots with EtherCAT User s Manual I659...
Page 72: ...2 Specifications 2 18 i4L Robots with EtherCAT User s Manual I659...
Page 122: ...3 Installation 3 50 i4L Robots with EtherCAT User s Manual I659...
Page 138: ...4 Operation 4 16 i4L Robots with EtherCAT User s Manual I659...
Page 169: ...I Index I 1 i4L Robots with EtherCAT User s Manual I659 I...
Page 172: ...Index I 4 i4L Robots with EtherCAT User s Manual I659...
Page 173: ......