3
Place the outer link cover on the robot in its original position.
4
Replace four of the outer link cover fastening screws as indicated below.
Apply thread lock to the screws and tighten using a 2.5 mm hex bit to a torque of 2.9 N-m.
5
Fasten two wire harness retaining clips (23477-000) to the outer link using two screws that
were previously removed in the locations shown below.
Apply thread lock to the screws and tighten using a 2.5 mm hex bit to a torque of 2.9 N-m.
6
Screw the stand-off studs (22873-000) into the inner bracket.
Apply thread lock to the stand-off studs and tighten using a 6 mm socket to a torque of 2.9 N-
m.
7
Place the pneumatic valve assembly near the stand-off studs and then insert four socket head
cap screws (51006-67025) with lock washers (18913-000) into the valve manifold to secure it
to the robot in the orientation shown below.
Apply thread lock to the socket head cap screws and tighten using a 3 mm hex bit to a torque
of 2.9 N-m.
3 Installation
3-17
i4L Robots with EtherCAT User's Manual (I659)
3-4
Installing Optional Equipment
3
3-4-4
Pneumatic V
alve Kit Installation Procedure
Summary of Contents for i4-350L
Page 1: ...i4L Robots with EtherCAT User s Manual i4 350L i4 450L i4 550L I659 E 01...
Page 6: ...Manual Information 4 i4L Robots with EtherCAT User s Manual I659...
Page 54: ...1 Overview 1 26 i4L Robots with EtherCAT User s Manual I659...
Page 72: ...2 Specifications 2 18 i4L Robots with EtherCAT User s Manual I659...
Page 122: ...3 Installation 3 50 i4L Robots with EtherCAT User s Manual I659...
Page 138: ...4 Operation 4 16 i4L Robots with EtherCAT User s Manual I659...
Page 169: ...I Index I 1 i4L Robots with EtherCAT User s Manual I659 I...
Page 172: ...Index I 4 i4L Robots with EtherCAT User s Manual I659...
Page 173: ......