Additional Information
Refer to the
T20 Pendant User's Manual (Cat. No. I601)
for additional information.
Precautions for Correct Use
If Teach Pendant cabling is installed, the jumper plug or the Teach Pendant must be connected
to satisfy safety circuits and allow High Power to be enabled.
Pins
Description
Additional Information
1, 9
Pendant E-stop button channel 1
Connected to the pendant's integrated E-stop button.
2, 10
Pendant E-stop button channel 2
3, 11
Pendant enable switch channel 1
Connected to the pendant's integrated enable switch.
4, 12
Pendant enable switch channel 2
6
24 VDC pendant supply
7
Serial communications TXD
Pendant serial communications transmit signal.
8
Serial communications RXD
Pendant serial communications receive signal.
13
Serial communications GND
Pendant serial communications ground signal.
Shield
Ground shield
5, 14, 15
Reserved for future use.
XMCP Jumper Plug
The XMCP jumper plug is used when there is no T20 pendant adapter cable connected.
X
M
CP
P
LUG
10
0
52
-000
WARNING
Never run a robot system with all jumpers installed. This would leave the system
with no E-Stops.
Additional Information
• The XMCP jumper plug is supplied with the robot.
• The part number for the XMCP jumper plug is 10052-000.
3 Installation
3-41
i4H Robots User's Manual (I660)
3-9
Installing Safety Equipment
3
3-9-2
Safety Circuits
Summary of Contents for i4-650H
Page 1: ...i4H Robots User s Manual i4 650H i4 750H i4 850H I660 E 02...
Page 6: ...Manual Information 4 i4H Robots User s Manual I660...
Page 74: ...2 Specifications 2 20 i4H Robots User s Manual I660...
Page 142: ...5 Troubleshooting 5 6 i4H Robots User s Manual I660...
Page 176: ...Appendix A 16 i4H Robots User s Manual I660...
Page 177: ...I Index I 1 i4H Robots User s Manual I660 I...
Page 180: ...Index I 4 i4H Robots User s Manual I660...
Page 181: ......