Install the pneumatic line fittings in the bottom of the Secondary Interface Panel.
Apply Loctite thread lock 545 before inserting the fittings. Tighten the fittings to 9 N-m using a 3
mm hex bit.
12
Connect the fittings on the pneumatic valve assembly to the installed fittings under the Secon-
dary Interface Panel using the supplied pneumatic lines.
Connect the valve fittings to the corresponding ports on the Secondary Interface Panel as
shown in the following figure.
Port 1
Port 2
Port 3
Port 4
Port 5
Port 6
13
Connect the pneumatic valve assembly solenoids to the outer link control board using the pro-
vided wiring harness.
Use the diagram below to understand the correct connections.
Position the wire harness in a location that prevents it from interfering with moving parts such
as a fan or belt.