Cleaning the Robot
Clean the exterior of the robot as needed. Inspect the external surface of the robot frequently when
used in a dirty environment.
Remove any dirt and debris from the exterior of the robot. Debris can accumulate around robot joints.
Take extra effort to clean around these areas.
WARNING
Do not use organic solvents to clean any part of the robot. Organic solvents might
damage electronics resulting in an unsafe operating state that could cause injury or
damage to equipment.
6-1-10
Bellows Inspection
Check the bellows each week for cracks, wear, or damage and replace if necessary. Refer to the
6-1-11 Bellows Replacement Procedure
on page 6-8 for replacement and installation steps.
6-1-11
Bellows Replacement Procedure
Use the following procedure to replace bellows.
Precautions for Correct Use
Never release the z-axis brake while the quill clamp collar is loose or removed. This can allow
the quill to fall out of the robot.
Additional Information
Refer to
3-4-4 Bellows Installation Procedure
on page 3-8 for more information.
The following items are required for this procedure.
• One of the following bellows replacement kits applicable to your robot.
• Standard quill length (210 mm): 19464-103F
• Long quill length (410 mm): 19464-104F
• 2.5 mm hex key
• 3 mm hex key
Make the following considerations before installing bellows.
• If cables or tubing are routed through the center of the quill, they must be removed before beginning
this procedure.
• The tool flange must be removed if the lower bellows is being replaced. Make all necessary prepara-
tions and considerations before removing the tool flange. Refer to
6-2-1 Replacing the Tool Flange
on page 6-12 for more information.
• The procedure removes the upper bellows first and then the lower bellows next.
• To simplify installation, the Joint 3 quill should be positioned in approximately the middle position.
• The upper and lower bellows are identical and interchangeable.
• A bellows replacement kit includes the upper and lower bellows items.
1
Begin the upper bellows removal by removing the large clamp from the upper bearing adapter
using a 2.5 mm hex bit.
6 Maintenance
6-8
i4H Robots User's Manual (I660)
Summary of Contents for i4-650H
Page 1: ...i4H Robots User s Manual i4 650H i4 750H i4 850H I660 E 02...
Page 6: ...Manual Information 4 i4H Robots User s Manual I660...
Page 74: ...2 Specifications 2 20 i4H Robots User s Manual I660...
Page 142: ...5 Troubleshooting 5 6 i4H Robots User s Manual I660...
Page 176: ...Appendix A 16 i4H Robots User s Manual I660...
Page 177: ...I Index I 1 i4H Robots User s Manual I660 I...
Page 180: ...Index I 4 i4H Robots User s Manual I660...
Page 181: ......