background image

 

Mini Contactor Relays 4-pole

 

J7KNA-AR

7

Mini Contactor Relays 4-pole

J7KNA-AR

Main contactor

• AC & DC operated

• 4-, 6- and 8-pole versions in different configurations

• Mirror contacts

• Screw fixing and snap fitting (35 mm DIN rail)

• Rated current = 10A (I

th

)

• Suitable for electronic devices (DIN 19240)

• Finger proof (BGV A2) 

Accessories

• 2- and 4-pole additional auxiliary contacts in different 

configurations

)

Approved Standards

Ordering Information

Model Number Legend

1. Mini Contactor Relays

1)

Mini Contactor

2)

AR:

Contactor Relay

3)

Combination of NO / NC contacts
22: 

2 NO 2 NC

31: 

3 NO 1NC

40: 

4 NO 0NC

4)

Coil voltage (AC operated)
24:

AC24V 50/60Hz

48:

AC48V 50Hz

110:

AC110-115V 50Hz,AC120-125V 60Hz 

230:

AC220-230V 50Hz,AC240V 60Hz

240:

AC230-240V 50Hz

400:

AC380-400V 50Hz,AC440V 60Hz

415:

AC400-415V 50Hz

550:

AC525-550V 50Hz,AC600V 60Hz

Coil voltage  (DC operated)
24D:

DC24V

48D:

DC48V

60D:

DC60V

110D: DC110V 
125D: DC125V
24VS: DC24V with diode
48VS: DC48V with diode
110VS: DC110V with diode
125VS: DC125V with diode

2. Aux. Contact Modules for Mini Motor Contactor Relays

1)

Auxiliary Contact Modules 

2)

A:

for mini  contactor relays

3)

Combination of NO/NC contacts
11:

1 NO 1 NC

02:

0 NO 2 NC

22:

2 NO 2 NC

40:

4 NO 0 NC

Standard

Guide No (US,C)

UL

NKCR, NKCR7

IEC 947-5-1

see page 95

VDE 0660

EN 60947-5-1

J7KNA-

##

-

##

-

#####

1

2

3

4

J73KN-

##

-

##

-

#

1

2

3 4

Summary of Contents for J7KNA-AR

Page 1: ...22 2 NO 2 NC 31 3 NO 1NC 40 4 NO 0NC 4 Coil voltage AC operated 24 AC24V 50 60Hz 48 AC48V 50Hz 110 AC110 115V 50Hz AC120 125V 60Hz 230 AC220 230V 50Hz AC240V 60Hz 240 AC230 240V 50Hz 400 AC380 400V 50Hz AC440V 60Hz 415 AC400 415V 50Hz 550 AC525 550V 50Hz AC600V 60Hz Coil voltage DC operated 24D DC24V 48D DC48V 60D DC60V 110D DC110V 125D DC125V 24VS DC24V with diode 48VS DC48V with diode 110VS DC11...

Page 2: ...il voltages see page 10 DC Solenoid Operated Contacts Distinc Number acc to DIN EN 50011 Ratings Thermal Rated Current Ith A Type Pack pcs Weight kg pc NO NC AC15 230V A 400V A Coil voltage 24V DC 2 5W 4 pole With Screw Terminals 4 40E 3 2 10 J7KNA AR 40 24D VS 1 10 0 19 3 1 31E 3 2 10 J7KNA AR 31 24D VS 1 10 0 19 2 2 22E 3 2 10 J7KNA AR 22 24D VS 1 10 0 19 1 with built in coil suppressor diode ze...

Page 3: ... 1 1 33Y 3 3 J73KN A 02 0 2 24Y 2 4 J73KN A 40 4 0 62Y 6 2 J73KN A 22 2 2 44Y 4 4 DC Solenoid Operated Wiring Diagrams Distinc Number acc to DIN EN 50011 Auxiliary Contact Blocks Contactor Relay with Auxiliary Contact Type NO NC Block Distinc Number according to DIN EN 50011 NO NC 4 pole With Screw Terminals 40E J73KN A 11 1 1 51E 5 1 Preferable combinations with distinctive letter E according to ...

Page 4: ...4 60 90 90 95 100 105 90 95 100 105 95 95 100 105 110 95 100 105 110 100 100 110 115 100 105 110 115 105 105 110 115 120 105 110 115 120 110 110 115 120 125 110 115 120 125 200 200 210 220 195 205 210 220 Suffix Voltage Marking Rated Control Voltage Us to contactor type e g at the coil range for 50Hz 60Hz J7KNA AR 40 230 for 50Hz V for 60Hz V min V max V min V max V 210 205 215 220 230 205 215 220...

Page 5: ...ith reduced control voltage range 0 9 up to 1 0 x Us and with reduced thermal rated current Ith to Ie AC15 enclosed C 40 to 40 Storage C 40 to 90 Short circuit protection short circuit current 1kA contact welding not accepted max fuse size gL gG A 20 20 20 20 Power consumption of coils AC operated inrush VA 25 sealed VA 4 5 W 1 2 DC operated inrush W 2 5 2 5 sealed W 2 5 2 5 Operation range of coi...

Page 6: ...for use on a capability of delivering not more than rms A V Rated voltage V AC 600 600 Auxiliary Contacts cULus heavy pilot duty AC A600 A600 standard pilot duty DC Q600 Q600 AC and DC operated with screw terminals Auxiliary Contact Blocks J7KNA AR J73KN A In the interest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS Cat No J04E ...

Reviews: