3.11 Wiring I/O Connectors
36
3.11 Wiring I/O Connectors
Note: Do not apply excessive force when connecting or disconnecting the cable or the
connector. Damage to the cable or connectors may cause the product to stop
operating or malfunction.
• Separate the I/O cable at least 300 mm from power lines (i.e., high-voltage lines, such as the
power supply line and servomotor main circuit cable).
• Be sure that the maximum wiring length of the I/O cable is 3 m.
• The longer the I/O cable is, the lower the maximum transmission frequency will be.
Connection Diagram for Standard I/O Cable (supplied by Yaskawa Electric Company
If a user-prepared I/O cable is used for relaying, refer to the following connection diagram for the
standard cable (JZSP-CHI003-
Cable with Connector) and wire the encoder cable.
Note: Pin numbers are given on the connector as well.
Pin
No.
I/O
Code
Signal Name
Lead
Color
Dot Mark
Number
Color
1
Input
CW, PULS
Reverse pulse,
Reference pulse
Orange
1
Black
2
Input
/CW, /PULS
Red
3
Input
CCW, SIGN
Forward pulse,
Reference sign
Light
gray
Black
4
Input
/CCW, /SIGN
Red
5
Input
+24VIN
External input power supply
White
Black
6
Input
/S-ON
Servo ON
Red
7
Output
SG-COM
Output signal ground
Yellow
Black
8
Input
CLR
Position deviation Pulse
clear
Red
9
Input
/CLR
Pink
Black
10
Output
PCO
Phase-C signal
Red
11
Output
SG-PCO
Phase-C signal ground
Orange
2
Black
12
Output
ALM
Servo alarm
Red
13
Output
/BK
Brake
Light
gray
Black
14
Output
/COIN
Positioning completion
Red
Shell
−
−
FG
−
−
Controller
Separate by
300 mm or more
Power supply
NOTE
(
φ
5.6)
Plug (14P): 10114-6000EL
Shell Kit: 10314-52A0-008
3M
Host controller end
SERVOPACK end
8 9 10 11
13 14
12
5
4
3
2
7
6
SERVOPACK Connector (Plug)
(Viewed from soldered side)
SERVOPACK Connector (Plug)
(Viewed from soldered side)
SERVOPACK Connector (Plug)
(Viewed from soldered side)
1
SERVOPACK Connector (Plug)
(Viewed from soldered side)
TOEP_C710806_01A_0_0.book Seite 36 Montag, 2. Juli 2007 4:24 16