background image

1

New Product

Liquid Leakage Position Sensor

K7L-UP-FLK

Pinpoint Liquid Leakage Detection at Up to 600 m. 
Easy Setup and Installation.

• Even unseen places under the floor can be pinpointed and restored.

• Detection of the extent of leakage and occurrence of a leak in another 

place.

• Monitoring at Up to 600 m with a Single Controller.

• The disconnection detection function constantly monitors for cable errors.

• A Wide Selection of Outputs from a Relay Output to Communications 

Output to Suit the System.

• The Sensing Cable is made of fluororesin for improved resistance to 

chemicals.

• Cables with connectors are easy to install.

• UL approval.

List of Models

Note: 1.

The Controller cannot be ordered separately.

2.

Included with the K7L-UP-FLK, but can be ordered separately.

Basic configuration

*

Area Separators can be used to enable accurately identifying the detection area in which a leak has occurred even when the leak occurs near 
an area boundary.

Product name

Model

Quantity

Liquid Leakage Position Sensor

K7L-UP-FLK 100-240VAC

1

Controller 

(See Note.1) 

K7L-UP-FLK  100-240VAC

1

Connecting Cable

 (See Note.2)

F03-21UP-CC

1

Terminator

 (See Note.2)

F03-20UP-TC

1

Sensing Cable

F03-16UP-C-2M

2 m

1

F03-16UP-C-5M

5 m

1

F03-16UP-C-10M

10 m

1

F03-16UP-C-30M

30 m

1

Junction Cable

F03-21UP-JC

1

Area Separator

F03-20UP-AS

1

---

Cable Stickers

F03-25

30 Stickers per bag

1

Connector

Connector

Connector

Connector

Connector

Connector

*

*

Summary of Contents for K7L-UP-FLK

Page 1: ...easy to install UL approval List of Models Note 1 The Controller cannot be ordered separately 2 Included with the K7L UP FLK but can be ordered separately Basic configuration Area Separators can be us...

Page 2: ...DC Mechanical 20 million outputs Electrical 80 000 outputs 24 VDC at 5 mA reference value 100 m max default 4 to 20 mA output Allowable load resistance Resolution Error Steady state At error detection...

Page 3: ...in X Y and Z directions Shock resistance 130 m s2 3 times each for 3 axes in six directions Weight Sensor only Approx 185 g Memory protection EEPROM non volatile memory Installation environment Insta...

Page 4: ...8 bits Stop bit length 1 2 bits Set automatically no setting depending on the vertical parity setting Without vertical parity 2 bit With vertical parity 1 bit Error detection Vertical parity none even...

Page 5: ...combination with a button Up Cursor Button Moves the selected item up Moves the selected item up Moves the number or character forward Down Cursor Button Moves the selected item down Moves the selecte...

Page 6: ...disconnection output contacts NC Free terminal 4 Leakage disconnection output contacts 12 External reset 5 RS 485 B 13 External reset 6 RS 485 A NC Free terminal 7 Linear outputs 15 Detect wire Red C...

Page 7: ...e internally isolated Internal Block Diagram 12 13 COM 6 V 4 7 k 7 8 L 500 Max 2 1 Relay 3 4 Relay Power supply circuit X X Linear outputs circuit Drive circuit Reset circuit External reset 4 to 20 mA...

Page 8: ...is function changes the length of the Sensing Cable to any value When there is a discrepancy between the actual length and the measured length this value can be revised to any value for compensation O...

Page 9: ...ession may not be sufficient Dimensions Unit mm Product name Model A Connecting Cable F03 21UP CC B Sensing Cable F03 16UP C M 1 C Area Separator 2 F03 20UP AS D Junction Cable 3 F03 21UP JC E Termina...

Page 10: ...kel Insulation coating Fluororesin Connector materials Metallic parts Brass with nickel plating Resin parts Polyolefine resin Insulation resistance 10 M min Ambient temperature 10 to 55 C Ambient humi...

Page 11: ...pearance Dimensions Junction Cable F03 21UP JC 67 4 7 15 dia 2 050 M12 15 dia 63 Adhesive tape 25 2 15 1 3 5 0 5 1 Material SUS304 Area Separator Leak positions in meters can be divided into up to 20...

Page 12: ...the product in parallel with or bundled with power lines Using separate conduits or ducts and shielded cables can also be effective 14 Do not allow pieces of metal wire clippings or fine metallic sha...

Page 13: ...13 MEMO...

Page 14: ...MEMO 14...

Page 15: ...ons or uses not described in this document Nuclear energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and instal...

Page 16: ...Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Tokyo JAPAN OMRON ASIA PACIFIC PTE LTD No 438A A...

Reviews: