background image

General-purpose Relay

 

MK-I/-S

A-45

Elec

trome

c

ha

ni

c

a

Re

la

ys

General-purpose Relay

MK-I/-S

Exceptionally Reliable General-purpose 
Relay Features Mechanical Indicator/Push 
Button

• Breaks relatively large load currents despite small size.

• Long life (minimum 100,000 electrical operations) assured by 

silver contacts.

• Built-in operation indicator (Mechanical, LED), push button, 

diode surge suppression, varistor surge suppression.

• Standard models are UL, CSA, SEV, DEMKO, NEMKO, 

SEMKO, TÜV (IEC), and VDE.

• Conforming to CENELEC standards.

Model Number Structure

Model Number Legend

Standard Models

Special Accessories

1

2

3

4

5

6

1. Contact 

Form 

 

2: DPDT 

 3: 

3PDT

2. Cover 

P: Dust cover

3.  Internal Connection Construction 
 

Blank: Standard 

 

2 or 5:  Non-standard connection 

 (Refer 

to 

Terminal Arrangement/ 

 

Internal Connections)

4.  Mechanical Indicator Push Button 
 

S: 

Mechanical indicator and 

  

push 

button 

 I: 

Mechanical 

indicator

5. Approved 

Standards 

 Blank: 

UL, 

CSA, 

DEMKO, 

NEMKO 

  

SEMKO, 

SEV, 

TÜV 

 VD:  VDE

6. Rated 

Voltage 

 (Refer 

to 

Coil Ratings

)

MK                  -      -

1

2

3

4

5

6

7

8

1. Contact 

Form 

 2: DPDT 
 3: 3PDT

2. Cover 

 P: Dust 

cover

3. Classification 

 N: LED 

indicator 

 D: Diode 
 V: Varistor 
 

ND:  LED indicator and diode 

 

NV:  LED indicator and varistor

4. Coil 

Polarity 

 Blank: 

Standard 

 1:  Reverse 
 (Refer 

to 

Terminal Arrangement/ 

 Internal 

Connections)

5.  Internal Connection Construction 

 Blank: 

Standard 

 2 

or 

5: 

Non-standard 

connection 

 (Refer 

to 

Terminal Arrangement/ 

 Internal 

Connections)

6.  Mechanical Indicator Push Button

 

S: 

Mechanical indicator and 

  

push 

button 

 I: 

Mechanical 

indicator

7. Approved 

Standards 

 

Blank:  UL and CSA only 

 

VD: 

VDE (N and D models only)

8. Rated 

Voltage 

 (Refer 

to 

Coil Ratings

)

MK                       -      -      -

Summary of Contents for MK-I -

Page 1: ...dard 2 or 5 Non standard connection Refer to Terminal Arrangement Internal Connections 4 Mechanical Indicator Push Button S Mechanical indicator and push button I Mechanical indicator 5 Approved Standards Blank UL CSA DEMKO NEMKO SEMKO SEV TÜV VD VDE 6 Rated Voltage Refer to Coil Ratings MK 1 2 3 4 5 6 7 8 1 Contact Form 2 DPDT 3 3PDT 2 Cover P Dust cover 3 Classification N LED indicator D Diode V...

Page 2: ...A SEV DEMKO NEM KO SEMKO TÜV VDE Non standard MK2P2 I VD MK2P2 S VD 3PDT Standard MK3P I VD MK3P S VD Non standard MK3P2 I VD MK3P5 I VD MK3P2 S VD MK3P5 S VD LED Indicator VDE approved DPDT Standard MK2PN I VD MK2PN S VD AC DC UL CSA VDE Non standard MK2PN 2 I VD MK2PN 2 S VD 3PDT Standard MK3PN I VD MK3PN S VD Non standard MK3PN 2 I VD MK3PN 2 S VD MK3PN 5 I VD MK3PN 5 S VD Diode VDE approved DP...

Page 3: ...180 mA 202 mA 16 9 Ω 24 V 88 0 mA 98 0 mA 62 0 Ω 50 V 39 0 mA 46 3 mA 330 Ω 100 V 24 8 mA 28 4 mA 1 010 Ω 110 V 21 0 mA 24 7 mA 1 240 Ω 120 V 18 0 mA 20 2 mA 1 520 Ω 200 V 12 1 mA 14 2 mA 4 520 Ω 220 V 11 0 mA 12 9 mA 5 130 Ω 230 V 10 5 mA 12 3 mA 6 170 Ω 240 V 9 2 mA 10 3 mA 6 450 Ω DC 6 V 255 mA 23 5 Ω 15 min of rated voltage Approx 1 5 W 12 V 126 mA 95 Ω 24 V 56 mA 430 Ω 48 V 29 5 mA 1 630 Ω 10...

Page 4: ...trength 2 500 VAC 50 60 Hz for 1 min between coil and contacts 1 000 VAC 50 60 Hz for 1 min between contacts of same polarity terminals of the same polarity 2 500 VAC 50 60 Hz fro 1 min between current carrying parts non current carrying parts and termi nals of opposite polarity Vibration resistance Destruction 10 to 55 to 10 Hz 0 75 mm single amplitude 1 5 mm double amplitude Malfunction 10 to 55...

Page 5: ...ns 6 to 110 V 6 to 240 V 10 A 250 V NO cosφ 1 5 A 250 V NC cosφ 1 10 A 28 V NO 5 A 28 V NC 7 A 250 V cosφ 0 4 100 000 cycles Coil ratings Contact ratings Operations 6 to 110 V 6 to 240 V 10 A 250 V NO cosφ 1 5 A 250 V NC cosφ 1 100 000 cycles Coil ratings Contact ratings Conditions Operations 6 12 24 48 100 110 V 6 12 24 50 100 110 115 120 200 220 230 240 V 10 A 250 V cosφ 1 10 A 28 V 7 A 250 V co...

Page 6: ... 30 50 70 100 500 700 300 1 000 100 10 28 VDC resistive load 250 VAC resistive load 120 VAC resistive load Electrical Endurance AC resistive load Maximum Switching Power Endurance x10 3 operations Switching current A Switching current A Switching voltage V 250 VAC inductive load DC resistive load 28 VDC max AC inductive load ...

Page 7: ...xceeding 5 A may lead to burning Round terminals cannot be used for finger protection models Use Y shaped terminals 0 8 34 5 max 52 5 max 34 5 max Socket Surface mounting Socket for track or screw mounting Finger protection models Maximum carry current 10 A 5 A 2 poles PF083A E PF083A 3 poles PF113A E PF113A 7 33 4 35 4 2 3 5 7 34 4 35 4 2 3 5 33 0 2 33 0 2 4 PF083A E Conforming to EN 50022 Mounti...

Page 8: ...10 1000 500 7 3 0 15 35 0 3 27 0 15 1 4 5 15 25 25 25 25 15 10 10 1000 4 35 0 3 27 24 16 29 2 1 1 5 This dimension applies to the PFP 50N Mounting Track A total of twelve 25 x 4 5 elliptic holes is provided with six holes cut from each track end at a pitch of 10 mm PFP 100N PFP 50N Conforming to EN 50022 PFP 100N2 Conforming to EN 50022 74 3 84 3 PF083A E PF113A E 77 8 See note 87 8 See note Two p...

Page 9: ...2 22 14 24 A1 A2 11 21 12 22 11 21 14 24 A1 A2 12 22 14 32 21 34 11 31 24 A1 A2 11 31 12 32 14 22 A1 A2 21 24 34 22 24 12 32 14 34 11 31 21 A1 A2 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 1 2 3 4 5 6 7 8 9 10 11 MK2P I S MK2P2 I S MK3P I S MK3P2 I S MK3P5 I S MK2P I VD S VD MK2P2 I VD S VD MK3P I VD S VD MK3P2 I VD S VD MK3P5 I VD S VD MK2PN I S MK2PN 2 I S MK...

Page 10: ...K2PD 2 I S MK3PD I S MK3PD 2 I S MK3PD 5 I S MK2PN1 I S MK2PN1 2 I S MK3PN1 I S MK3PN1 2 I S MK3PN1 5 I S LED Indicator Type DC Coil Standard Polarity LED Indicator Type DC Coil Reverse Polarity Diode Type DC Coil Standard Polarity 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 ...

Page 11: ...5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 14 A1 11 21 A2 24 12 22 14 A1 11 21 A2 24 12 22 12 14 21 A1 11 22 24 32 34 A2 31 31 32 22 34 A2 A1 24 14 12 11 21 22 21 24 32 34 A2 31 11 A1 14 12 12 22 14 A1 11 21 A2 24 14 A1 11 21 A2 24 12 22 12 14 21 A1 11 22 24 32 34 A2 31 31 32 22 34 A2 24 14 12 11 21 22 21 24 32 34 A2 31 11 A1 14 12 A1 12 22 14 A1 11 21 A2 24 14 A1 11 21 A2 24 12 22 12 14 21 A1 11 22 ...

Page 12: ...12 22 12 14 21 A1 11 22 24 32 34 A2 31 31 32 22 34 A2 A1 24 14 12 11 21 22 21 24 32 34 A2 31 11 A1 14 12 MK2PD1 I VD S VD MK2PD1 2 I VD S VD MK3PD1 I VD S VD MK3PD1 2 I VD S VD MK3PD1 5 I VD S VD MK2PN I VD S VD MK2PN 2 I VD S VD MK3PN I VD S VD MK3PN 2 I VD S VD MK3PN 5 I VD S VD VDE Approved Type Diode Type DC Coil Reverse Polarity VDE Approved Type LED Indicator Type AC Coil In the interest of ...