General-purpose Relay
MK-I/-S
A-49
Elec
trome
c
ha
ni
c
a
l
Re
la
ys
■
Approved Standards
The following ratings apply to all models.
UL 508 (File No. E41515)/CSA 22.2 No.0/14 (File No. LR35535)
SEV, DEMKO, NEMKO
SEMKO
TÜV (VDE 0435 Teil 201/05’90, IEC 255 Teil 1-00/’75, EN 60950/’88
(TÜV File No.: R9051410)
VDE (VDE 0435 Teil 201/05’83, IEC 255 Teil 1-00/’75)
(VDE File No.: NR 5340)
Coil ratings
Contact ratings
Operations
6 to 110 VDC
6 to 240 VAC
10 A, 28 VDC (resistive)
10 A, 250 VAC (resistive)
7 A, 250 VAC (general use)
100,000 cycles
Coil ratings
Contact ratings
Operations
6 to 110 V
=
6 to 240 V
~
10 A, 250 V
~
(NO) (cos
φ
= 1)
5 A, 250 V
~
(NC) (cos
φ
= 1)
10 A, 28 V
=
(NO)
5 A, 28 V
=
(NC)
7 A, 250 V
~
(cos
φ
= 0.4)
100,000 cycles
Coil ratings
Contact ratings
Operations
6 to 110 V
=
6 to 240 V
~
10 A, 250 V
~
(NO) (cos
φ
= 1)
5 A, 250 V
~
(NC) (cos
φ
= 1)
100,000 cycles
Coil ratings
Contact ratings
Conditions
Operations
6, 12, 24, 48, 100
110 V
=
6, 12, 24, 50, 100, 110
115, 120, 200, 220
230, 240 V
~
10 A, 250 V
~
(cos
φ
= 1)
10 A, 28 V
=
7 A, 250 V
~
(cos
φ
= 0.4)
IEC 255-1-00 Item 3.1.4
Pollution Degree 3,
Overvoltage Category II
Pick up class - class 2
Temperature class - class b
100,000 cycles
Coil ratings
Contact ratings
Conditions
Operations
6, 12, 24, 48, 100
110 V
=
6, 12, 24, 50, 100, 110
115, 120, 200, 220
230, 240 V
~
10 A, 250 V
~
(cos
φ
= 1)
10 A, 28 V
=
7 A, 250 V
~
(cos
φ
=
0.4)
C/250 - class 1, class C
100,000 cycles