3 Functions of NB-Designer
3-302
NB-series Programmable Terminals NB-Designer Operation Manual(V106)
Set the screen security levels and make Frame 10 correspond to Security Level 1, Frame
11 correspond to Security Level 2, …, and Frame 24 correspond to Security Level 15.
(3) Perform the offline test or download it to the screen to check the password level function.
The software opens 32 users and 32 operation permissions for free use. The users and operation
permission can be set separately, and the operation permission is not limited to the users. And the
online user addition/deletion and permission modification can be done in the PT.
1
User Permission Setting
Check the [Enabled] option and input the contents to the User Name, Password, Logoff Time
and Authorization.
User Name: Refers to the login name and the defaults are usr0 to usr31. The user name
supports any characters.
Password: Refers to the login password, and the default is 888888. The password only
supports the number instead of the other characters. The password ranges from 1 to
4294967295. And 0 can’t be used for setting password.
Logout Time: Refers to the valid time for this user permission and the default is 10 minutes.
After 10 minutes, this user permission will be automatically cancelled, and the operation
permission can be obtained by inputting the password again. The logoff time ranges from 0 to
4294967295 minutes. When the Logout Time is specified to 0 minute, the user permission is
always valid.
3-10-6 User Permission Setting
Summary of Contents for NB10W-TW01B
Page 4: ......
Page 10: ...Terminology 6 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Page 528: ...8 Web Interface 8 10 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Page 544: ...Appendices A 16 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Page 546: ...Revision 2 NB series Programmable Terminals NB Designer Operation Manual V106 ...
Page 547: ......