3 Functions of NB-Designer
3-396
NB-series Programmable Terminals NB-Designer Operation Manual(V106)
Station No. use the special memories (LW9416 to LW9431). When the special memories are
used, the Station No. is determined by the value of the memory.
31
PT Mask and PLC Station No. Mask
PT Mask function:
LW9400 to LW9415 (totaling 256 bits) correspond to PT Station No. 0 to 255. When these bits
are set to ON, the access to the corresponding PT numbers will be masked.
PLC Station No. Mask Function:
9264~9279
Mask code of PLC
Station No.(COM 2)
Each bit corresponds to one Station No. of COM 2 (i.e. 9264.0
corresponds to Station No. 0... and 9279.F corresponds to Station
No. 255). When the bit is turned ON, the communication
corresponding to Station No. will be masked (read/write).