Enabling Switch
Section 3-3
3-3
Enabling Switch
3-3-1
Overview
In contrast to the emergency stop switch, which lets a worker intentionally
stop the machine in case of an emergency, the enabling switch makes it eas-
ier to avoid danger with no conscious decision by a worker. When work is
required in hazardous areas, e.g, during maintenance, devices with enabling
switches provide an important safety measure by preventing unexpected
operations from occurring while work is underway in the those areas.
Manual operation of devices is permitted while the enabling switch is lightly
pressed. At soon as a hazardous situation arises, however, operation is
stopped if the worker instinctively either lets go of the enabling switch or
grasps it more tightly.
Some standards, such as the ANSI/RIA R15.06 and CSA/Z434-03 Industrial
Robot Standards and the ANSI/B11.19 Machine Tool Standards, require the
use of enabling switches. In EN 60204-1, enabling switches are not required
but are recommended as auxiliary devices.
External Connection
Diagram
The status of the enabling switch’s DPST-NO contact is output externally
using a hard-wired output from the Special Cable.
Pressure
ON
OFF
Ordinary pressure:
Turns ON
Pressed in:
Turns OFF
Enabling switch
Hard-wired DPST-NO contact (3-position)
ENB1A1
ENB2A1
ENB2A2
ENB1A2
ENB1 ENB2
NSH5
Enabling switch
DPST-NO
Special Cable
Safety
circuit
Summary of Contents for NSH5
Page 2: ......
Page 4: ...iv ...
Page 12: ...xii ...
Page 16: ...xvi ...
Page 24: ...xxiv EC Directives 6 ...
Page 58: ...34 Installing the Mounting Bracket Section 2 5 ...
Page 86: ...62 Connection Method Section 4 5 ...
Page 92: ...68 Precautions When Replacing the PT Section 5 4 ...
Page 98: ...74 General Specifications Appendix A ...
Page 99: ...75 Appendix B Dimensions 75 50 176 223 75 Four M4 70 5 16 5 ...
Page 102: ...78 Types of Memory Appendix C ...
Page 107: ...83 Recommended Enabling Circuits Appendix D Program Example ...
Page 108: ...84 Recommended Enabling Circuits Appendix D ...