116
Memory Table Entries and Bar Graph
Section 5-3
*1 LR 00000 to LR 00199 are converted to CIO 01000 to CIO 01199.
*2 The EM Area is supported only by the C200HX/HG/HE(-Z)E PLCs.
If the “number of registration words x 2” (“word setting window”) set with the
support tool is larger than the “number of character digits” (“character-string
display setting” window), the character-string may be broken halfway.
The range of respective area varies with the type of PLC. Refer to
Appendix H
Special Characters
(page 163).
Writing Numerals to Numeral Memory Table Entries
Since numeral memory table entries can be allocated to PLC words, it is pos-
sible to write data into the numeral memory tables from the PLC and to set the
initial values during screen data creation.
During the operation, the display contents are automatically updated so that
the contents of the numeral memory table entry being displayed are the same
as that of the PLC word.
Setting the Words of the Numeral Memory Table Entry
When creating the screen data by using the support tool, make the following
settings for each numbered numeral:
• Initialization setting
Set whether or not the PLC words are initialized with the numeral memory
table initial value registered to the screen data memory when the main
power supply is turned ON or reset.
• Number of registration words
Set the number of words within 2 words required for registering the numer-
al data. One word can store up to 4 digits. Two words can store up to 8 dig-
its.
• Setting the words for the numeral memory table entries
C
TC Area,
Counter PVs
No
Counter Area,
Counter PVs
No
TC Area,
Counter PVs
No
CU
---
---
---
---
TC Area,
Counter Completion Flags
No
W
---
---
---
---
WR Area
Not for Host
Link
TK
---
---
---
---
Task Flags
No
D
DM Area
OK
DM Area
OK
DM Area
OK
E
EM Area
*2
,
current bank
OK
EM Area,
current bank
Not for Host
Link
EM Area,
current bank
Not for Host
Link
E0_ to
EC_
---
---
---
---
EM Area,
EM banks 0 to C
Not for Host
Link
Symbol
C-series PLCs
Allocation
CV-series PLCs
Allocation
CS/CJ-series PLCs
Allocation
The numeral display area where the
numeral memory table entry 2 is
allocated
Defect
The bar graph display area where the
numeral memory table entry 4 is
allocated
Word
The contents are the same while they are
displayed.
Can be updated by the PLC.
NT11
PLC
Numeral memory
table
Summary of Contents for NT11 - 01-2004
Page 1: ...USER S MANUAL Cat No V084 E1 01 NT11 Programmable Terminal ...
Page 2: ...NT11 Programmable Terminal User s Manual Produced January 2004 ...
Page 3: ...iv ...
Page 5: ...vi ...
Page 13: ...xiv Safety Precautions 3 ...
Page 27: ...14 Before Operating Section 1 6 ...
Page 71: ...58 Connecting a Printer Section 2 8 ...
Page 119: ...106 Daily Report Display History Printing Function Section 4 10 ...
Page 157: ...144 Inspection and Cleaning Section 6 3 ...
Page 162: ...149 Appendix B Dimensions Body NT11 SF121 B EV1 38 2 7 5 218 203 113 98 ...
Page 163: ...150 Dimensions Appendix B ...
Page 165: ...152 Transporting and Storing the NT11 Appendix C ...
Page 183: ...170 Revision History ...
Page 186: ...NT11 Programmable Terminal Cat No V084 E1 01 USER S MANUAL ...