Setting the Conditions for Communications with the Host by Using the Memory Switches
Section 6-7
S
To quit the unit number setting screen without confirming the unit number set-
tings, press the “Abort” touch switch. The NT31/NT31C will return to the
memory switch setting screen (4/4) with the previous settings still in effect.
Reference: “Unit numbers” are numbers assigned to each PT when multiple PTs are con-
nected to one host, so that the host can identify the individual PTs. The units num-
bers that can be set differ according to the host model, as follows.
- C200HE(-ZE):
Unit numbers 0 to 3 (maximum of 4 PTs per host port)
- C200HG(-ZE), C200HX(-ZE):
Unit numbers 0 to 7 (maximum of 8 PTs per host port)
When making the settings, make sure there is no duplication of unit numbers
among PTs.
On completion of unit number setting, the NT31/NT31C returns to the memory
switch setting screen (4/4).
To set other memory switches, select the relevant screen using the [ ] (next
screen) or [ ] (previous screen) touch switch, then make the setting.
S
To confirm the settings and quit the memory switch setting screen, press the
“Quit” touch switch. The settings made last will be set and the NT31/NT31C will
return to the “MAINTENANCE MODE MENU” screen.
S
To quit the memory switch setting screen without confirming the settings, press
the “Abort” touch switch. The NT31/NT31C will return to the “MAINTENANCE
MODE MENU” screen with the previous settings still in effect.
6-7-5
Setting the Memory Link Method
Set the communication conditions for the host link method at serial port A or serial
port B by following the operation from the System Menu shown below. Check the
communication settings of the host to be used.
Select “Maintenance Mode”.
Select “Memory Switch”.
Summary of Contents for NT31 Series
Page 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Page 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Page 41: ...30 Before Operating Section 1 5...
Page 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Page 160: ...149...
Page 174: ...163...
Page 193: ...182...
Page 211: ...200...
Page 235: ...224 c Return to the screen on which screens are specified...
Page 262: ...251...
Page 360: ...349 It is not possible to control a gloval window by touch switch operation...
Page 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Page 476: ...465 Special Functions Section 7 16...
Page 495: ...484 OFF...
Page 610: ...599 Commands Responses Section 9 3...
Page 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...