Using the UPS monitoring software
and contact signal
7
7
■
UPS monitoring software
“PowerAct Pro (for Windows/Linux)” , “UPS service driver” and “UPS Power Manager (Mac)” UPS
monitoring software is included with this product. Refer to the table below for details about compat-
ibility. Choose which one to use based on the application. Refer to the table below for details about
compatibility. For further details about the software functions, refer to the separate "UPS Monitoring
Software Quick Installation Guide."
* If you do not use the UPS monitoring software and contact signal, this
step is not required.
• UPS monitoring software selection table
Model
OS
Communication
method
UPS monitoring software
Required op-
tions
(sold separate-
ly)
Reference
BN50S/
BN75S/
BN100S/
BN150S/
BN220S/
BN300S
Windows 7
Windows Vista
Windows Server2008
(including R2)
Serial
(RS232C or USB 1.1)
PowerAct Pro 4.x (Note 1)
Simple Shutdown software (Note 1)
-
➛
See 7-1
LAN
PowerAct Pro 4.x
(Slave Agent) (Note1)
SC20G
➛
See 8-1
Windows server2003
x64 Edition
Windows XP
x64 Edition
Serial
(RS232C or USB 1.1)
PowerAct Pro 4.x (Note 1)
Simple Shutdown software (Note 1)
-
➛
See 7-1
UPS service (OS standard) + UPS ser-
vice driver (included software)
-
➛
See 7-2
Contact signal (Note
2) (Note 4)
UPS service (OS standard)
SC07
BUC26
➛
See 7-3
LAN
PowerAct Pro 4.x (Slave Agent) (Note1)
SC20G
➛
See 8-1
Windows server2003
Windows XP/2000
Serial
(RS232C or USB 1.1)
PowerAct Pro 4.x (Note 1)
Simple Shutdown software (Note 1) (Note 6)
-
➛
See 7-1
UPS service (OS standard) + UPS ser-
vice driver (included software)
-
➛
See 7-2
Contact signal (Note
2) (Note 3)
UPS service (OS standard)
SC07
BUC26
➛
See 7-3
LAN
PowerAct Pro 4.x (Slave Agent) (Note1)
SC20G
➛
See 8-1
Windows NT 4.0
Contact signal (Note
2) (Note 3)
UPS service (OS standard)
SC07
BUC26
➛
See 7-3
LAN
Shutdown Agent
SC20G
➛
See 8-1
Linux (Note 2)
Serial
(RS232C or USB 1.1)
PowerAct Pro (Note 1)
-
➛
See 7-1
LAN
PowerAct Pro (Slave Agent) (Note1)
Shutdown Agent
SC20G
➛
See 8-1
Mac OS X v10.6/v10.5
Mac OS X Server
v10.6/v10.5
Serial
(USB 1.1)
PowerAct Pro 4.x (Note 1) (Note 5)
-
➛
See 7-1
LAN
PowerAct Pro 4.x (Slave Agent) (Note1)
SC20G
➛
See 8-1
Note 1:
The most recent version can be downloaded from our homepage (http://www.omron.co.jp/ese/).
Note 2:
Files cannot be automatically saved.
Note 3:
To automatically stop the UPS, it may be necessary to change the PC’s BIOS settings.
Change the PC’s BIOS settings so that the PC’s power supply is not cut after OS shutdown is performed.
Note 4:
The UPS automatically stops once the battery is depleted.
Note 5:
Compatible with Ver 4.1 or later, not with Power PC version.
Note 6:
Not compatible with Windows 2000.