64
Memory Mapping
Appendix A
A-2
Parameter / Command Mapping for K-Format Devices
The table below lists the Mapping of individual parameters in the Basic and Extended blocks on to the E5AK/
E5EK Intelligent Digital Controller. Refer to the E5AK and E5EK Operation Manuals (H083-E1-
@
,
H085-E1-
@
)
for more information
.
Parameter
Read/
Write
Parameter
Number
Remarks
Bas
ic
Setpoint
W
01
Special operation
W
--
Special Command is used to initiate Run or Stop.
• 0000 = Run
• 0001 = Stop
PV monitor
R
00
SP monitor
R
01
Status A group
R
--
Special Command is used to read Status A/Status B.
• 0000 = Status group A
• 0001 = Status group B
Status B group
R
Operation Execute
R
--
Response to Special Operation is returned.
Ext
ended
b
loc
k
Setpoint
W
01
Special operation
W
--
Special Command is used to initiate Run or Stop.
• 0000 = Run
• 0001 = Stop
Alarm Value 1
W
02
Alarm Value 2
W
03
PV monitor
R
00
SP monitor
R
01
Status A group
R
--
Special Command is used to read Status A/Status B.
• 0000 = Status group A
• 0001 = Status group B
Status B group
R
Operation Execute
R
--
Response to Special Operation is returned.
Summary of Contents for PROFIBUS DP GATEWAY
Page 1: ...OPERATION MANUAL PROFIBUS DP Gateway to Host Link Compoway F PRT1 SCU11 Cat No W01E EN 02 ...
Page 2: ...PRT1 SCU11 PROFIBUS DP Gateway Operation Manual Revised September 19 2005 ...
Page 3: ...iv ...
Page 15: ......
Page 31: ......
Page 71: ......
Page 77: ......
Page 81: ......