10.4 Model Specifications (Single-Phase 200 V Class)
SIEPCYEUOQ2V01A Q2V Technical Manual
295
10.4
Model Specifications (Single-Phase 200 V Class)
Table 10.5 Ratings (Single-Phase 200 V Class)
Model
B001
B002
B004
B006
B010
B012
B018
Maximum Applicable Motor
Output (kW)
HD
0.1
0.25
0.55
1.1
1.5
2.2
4.0
ND
0.2
0.18
0.37
0.75
1.1
2.2
3.0
-
Maximum Applicable Motor
Output (HP)
HD
1/6
1/4
1/2
1
2
3
5
ND
1/6
1/4
3/4
1.5
3
3
-
Input
Rated Input
Current (A)
HD
1.4
2.8
5.5
11
14.1
20.6
35.0
ND
2.0
5.0
7.3
13.8
20.2
24.0
-
Output
Rated Output
Capacity (kVA)
HD
0.3
0.6
1.1
1.9
3
4.2
6.7
ND
0.5
0.7
1.3
2.3
3.7
4.6
-
Rated Output
Current (A)
HD
0.8
1.6
3
5
8
11
17.6
ND
1.2
1.9
3.5
6
9.6
12.2
-
Overload Tolerance
•
HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is once every 10 minutes.
•
ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is once every 10 minutes.
Note:
Derating may be necessary for applications that start and stop frequently.
Carrier Frequency
HD: 10 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 15 kHz maximum.
HD: 8 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 15 kHz
maximum.
Maximum Output Voltage
Single-phase 200 V to 240 V
Note:
The maximum output voltage is proportional to the input voltage.
Maximum Output Frequency
•
V/f Control, OLVector, PM OLVector: 590 Hz
•
PM AOLVector: 270 Hz
•
EZ Vector: 120 Hz
Measures for
Harmonics
AC reactor
External options
Braking Device Braking Transistor
Standard internal characteristics
External
options
EMC Filter
EMC Filter
IEC61800-3
Category C1 (Conducted emission)
External
options
Power Supply
Rated Voltage/Rated Frequency
•
Single-phase AC power supply 200 V to 240 V at 50/60 Hz
•
DC power supply 270 V to 340 V
Permitted Voltage Fluctuation
-15% to +10%
Permitted Frequency Fluctuation
±5%
Input Power
(kVA)
HD
0.4
0.7
1.5
2.9
3.7
5.4
9.2
ND
0.5
1.3
1.9
3.6
5.3
6.3
-
*1
The maximum applicable motor output complies with 208 V motor ratings as specified in NEC Table 430.250. The rated output
current of the drive output amps must be equal to or more than the motor rated current.
*2
The maximum applicable motor output is based on 4-pole, general-purpose 220 V motor ratings. The rated output current of the drive
output amps must be equal to or more than the motor rated current.
*3
The rated output capacity is calculated with a rated output voltage of 220 V.
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...