10.5 Model Specifications (Three-Phase 400 V Class)
296
SIEPCYEUOQ2V01A Q2V Technical Manual
10.5
Model Specifications (Three-Phase 400 V Class)
Table 10.6 Ratings (Three-Phase 400 V Class)
Model
Duty Rating
4001
4002
4004
4005
4007
4009
4012
Maximum Applicable Motor
Output
(kW)
HD
0.37
0.55
1.1
1.5
2.2
3.0
4.0
ND
0.37
0.75
1.5
2.2
3.0
4.0
5.5
Maximum Applicable Motor
Output
(HP)
HD
1/2
3/4
2
3
3
4
5
ND
1/2
1
2
3
4
5
7.5
Input
Rated Input
Current (A)
HD
1.2
1.8
3.2
4.4
6.0
8.2
10.4
ND
1.2
2.1
4.3
5.9
8.1
9.4
14
Output
Rated Output
Capacity
(kVA)
HD
0.9
1.4
2.6
3.7
4.3
5.6
7
ND
0.9
1.6
3.1
4.1
5.4
6.8
9.1
Rated Output
Current (A)
HD
1.2
1.8
3.4
4.8
5.6
7.3
9.2
ND
1.2
2.1
4.1
5.4
7.1
8.9
11.9
Overload Tolerance
•
HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is once every 10 minutes.
•
ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is once every 10 minutes.
Note:
Derating may be necessary for applications that start and stop frequently.
Carrier Frequency
HD: 8 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 15 kHz maximum.
Maximum Output Voltage
Three-phase 380 V to 480 V
Note:
The maximum output voltage is proportional to the input voltage.
Maximum Output Frequency
•
V/f Control, OLVector, PM OLVector: 590 Hz
•
PM AOLVector: 270 Hz
•
EZ Vector: 120 Hz
Measures for
Harmonics
DC reactor
External options
Braking Device Braking Transistor
Standard internal characteristics
EMC Filter
EMC Filter
IEC61800-3
Category C2 (Conducted emission)
Power Supply
Rated Voltage/Rated Frequency
Three-phase AC power supply 380 V to 480 V at 50/60 Hz
Permitted Voltage Fluctuation
-15% to +10%
Permitted Frequency Fluctuation
±5%
Input Power
(kVA)
HD
1.1
1.6
2.9
4
5.5
7.5
9.5
ND
1.1
1.9
3.9
5.4
7.4
8.6
13
*1
The maximum applicable motor output complies with 380 V motor ratings as specified in Annex G of IEC 60947-4-1. The rated
output current of the drive output amps must be equal to or more than the motor rated current.
*2
The rated output capacity is calculated with a rated output voltage of 440 V.
Table 10.7 Ratings (Three-Phase 400 V Class)
Model
Duty Rating
4018
4023
4031
4038
4044
4060
Maximum Applicable Motor Output
(kW)
HD
5.5
7.5
11.0
15.0
18.5
22.0
ND
7.5
11.0
15.0
18.5
22.0
30.0
Maximum Applicable Motor Output
(HP)
HD
10
10
15
20
25
30
ND
10
15
20
25
30
40
Input
Rated Input
Current (A)
HD
15
20
29
39
50.5
59.7
ND
20
24
38
44
59.7
80.7
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...