11.20 Defaults by Drive Model and Duty Rating ND/HD
SIEPCYEUOQ2V01A Q2V Technical Manual
419
Name
Unit
Default
-
Drive Model
-
4023
4031
4038
4044
C6-01
ND/HD Duty
Selection
-
HD
ND
HD
ND
HD
ND
HD
ND
0
1
0
1
0
1
0
1
o2-04
Drive KVA
Selection
Hex.
9A
9C
9D
9E
E2-11
(E4-11, E5-
02)
Motor Rated
Power (kW)
kW
7.5
11
11
15
15
18.5
18.5
22
E2-06
(E4-06)
Motor Leak
Inductance
%
15.5
19.6
19.6
17.2
17.2
20.1
20.1
23.5
E2-10
(E4-10)
Motor Iron
Loss
W
263
385
385
440
440
508
508
586
E5-01
PM Mot Code
Selection
-
FFFF
FFFF
FFFF
FFFF
FFFF
FFFF
FFFF
FFFF
L2-02
RideThrough
Time@Power
Loss
s
1
1
2
2
2
2
2
2
L2-03
Min Baseblck
Time
s
0.8
0.9
0.9
1
1
1
1
1
L2-04
Powloss
Ramp
Time@recov
ery
s
0.3
0.3
0.3
0.6
0.6
0.6
0.6
0.6
L2-05
UV Detection
Lvl (Uv1)
-
380
380
380
380
380
380
380
380
L3-02
StallP
Level@Accel
%
150
120
150
120
150
120
150
120
L3-06
StallP
Level@Run
%
150
120
150
120
150
120
150
120
L3-24
Acc@Rated
Torque
s
0.175
0.265
0.265
0.244
0.244
0.317
0.317
0.355
L8-02
Overheat Alm
Level
°C
120
120
120
120
120
120
125
125
L8-09
Ground Fault
Selection
-
0
0
1
1
1
1
1
1
n1-03
HuntPrev
Time Constant
ms
10
10
10
10
10
10
10
10
n3-02
HSB CurrLim
Level
%
150
120
150
120
150
120
150
120
n5-02
Mot Inertia
Acceleration
Time
s
0.175
0.265
0.265
0.244
0.244
0.317
0.317
0.355
*1
Parameters within parentheses are for motor 2.
No.
Name
Unit
Default
-
Drive Model
-
4060
C6-01
ND/HD Duty Selection
-
HD
ND
0
1
o2-04
Drive KVA Selection
Hex.
9F
E2-11
(E4-11, E5-02)
Motor Rated Power (kW)
kW
22
30
b3-04
SpSrch V/F Gain
%
100
100
b3-06
Speed Curr Lev1 for Estimation
-
0.5
0.5
b3-08
Speed ACR PGain for Estimation
-
0.5
0.5
b3-26
Dir. Determ. Level
-
1000
1000
b8-03
eSave Filter Time
s
0.5
0.5
b8-04
eSave Coef. Value
-
103.58
92.54
C6-02
Carrier Frequency Selection
-
3
7
E2-01
(E4-01)
Mot Rated Current (FLA)
A
38.6
52.3
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...