11.21 Parameters Changed by PM Motor Code Selection
422
SIEPCYEUOQ2V01A Q2V Technical Manual
No.
Name
Unit
Motor Code (setting value of E5-01)
E1-06
Base Frequency
Hz
240
240
240
240
E1-09
Min Output Frequency
Hz
12
12
12
12
L3-24
Acc@Rated Torque
s
0.137
0.132
0.132
0.122
n5-02
Mot Inertia Acceleration
Time
s
0.137
0.132
0.132
0.122
n8-49
Heavy Load Id Current
%
0
0
0
0
◆
Yaskawa SMRD Series SPM Motors
Table 11.7 SMRD Series Motor Code Setting for Specification of 200 V at 1800 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Mot Code Selection
-
3000
3001
3002
Voltage Class
V
200
200
200
Capacity
kW
0.1
0.2
0.4
Motor Rotation Speed
min
-1
1800
1800
1800
E5-02
PM Mot Rated Power (kW)
kW
0.1
0.2
0.4
E5-03
PM Mot Rated Current (FLA)
A
0.64
1
1.9
E5-04
PM Mot Pole Count
-
6
6
6
E5-05
PM Mot Resistance (Ohms/Phase)
Ω
17.200
9.960
3.590
E5-06
PM d-Axis Inductance (mH/Phase)
mH
33.20
19.40
11.90
E5-07
PM q-Axis Inductance (mH/Phase)
mH
33.20
19.40
11.90
E5-09
PM BackEMF Vpeak (mV/(rad/ s))
mVs/rad
0.0
0.0
0.0
E5-24
PM BackEMF L-L Vrms (mV/rpm)
mV/min
-1
59.1
69.8
75.9
E1-04
Max Output Frequency
Hz
90.0
90.0
90.0
E1-05
Max Output Voltage
V
200.0
200.0
200.0
E1-06
Base Frequency
Hz
90.0
90.0
90.0
E1-09
Min Output Frequency
Hz
9.0
9.0
9.0
L3-24
Acc@Rated Torque
s
0.100
0.100
0.100
n5-02
Mot Inertia Acceleration Time
s
0.100
0.100
0.100
n8-49
Heavy Load Id Current
%
0.0
0.0
0.0
Table 11.8 SMRD Series Motor Code Setting for Specification of 200 V at 3600 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Mot Code Selection
-
3101
3102
3103
Voltage Class
V
200
200
200
Capacity
kW
0.2
0.4
0.75
Motor Rotation Speed
min
-1
3600
3600
3600
E5-02
PM Mot Rated Power (kW)
kW
0.20
0.40
0.75
E5-03
PM Mot Rated Current (FLA)
A
1.50
2.60
4.20
E5-04
PM Mot Pole Count
-
6
6
6
E5-05
PM Mot Resistance (Ohms/Phase)
Ω
3.340
1.560
0.541
E5-06
PM d-Axis Inductance (mH/Phase)
mH
6.58
3.82
2.24
E5-07
PM q-Axis Inductance (mH/Phase)
mH
6.58
3.82
2.24
E5-09
PM BackEMF Vpeak (mV/(rad/
s))
mVs/rad
0.0
0.0
0.0
E5-24
PM BackEMF L-L Vrms (mV/
rpm)
mV/min
-1
26.3
31.0
32.9
E1-04
Max Output Frequency
Hz
180.0
180.0
180.0
E1-05
Max Output Voltage
V
200.0
200.0
200.0
E1-06
Base Frequency
Hz
180.0
180.0
180.0
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...