SIEPCYEUOQ2V01A Q2V Technical Manual
479
The soft starter process occurs downstream from the PID function. The PID function input functions as the
frequency reference, the PID function output functions as the soft starter input, and the soft starter output
functions as the output frequency.
1 : Enab PID Softstart
The soft starter process occurs upstream from the PID function. The soft starter input functions as the frequency
reference, the soft starter output functions as the PID function input, and the PID function output functions as the
output frequency.
■
b5-55: PID Fback Mon Selection
No.
(Hex.)
Name
Description
Default
(Range)
b5-55
(0BE1)
PID Fback Mon Selection
Sets the monitor (
Ux-xx
) used as the PID Feedback. Set the
x-xx
part of the
Ux-xx [Monitor]
.
000
(000 - 999)
Note:
•
You cannot select
parameter U5-xx
.
•
This parameter is disabled when set to
000
.
■
b5-56: PID FdbkMon Gain
No.
(Hex.)
Name
Description
Default
(Range)
b5-56
(0BE2)
PID FdbkMon Gain
Sets the gain for the monitor set in
b5-55 [PID Fback Mon Selection]
.
1.00
(0.00 - 10.00)
■
b5-57: PID FdbkMon Bias
No.
(Hex.)
Name
Description
Default
(Range)
b5-57
(11DD)
PID FdbkMon Bias
Sets the bias for the monitor specified in
b5-55 [PID Fback Mon Selection]
.
0.00
(-10.00 - +10.00)
■
b5-58 to b5-60: PID Setpoints 2 to 4
No.
(Hex.)
Name
Description
Default
(Range)
b5-58 to b5-60:
(1182 - 1184)
RUN
PID Setpoints 2 to 4
Sets the PID setpoint when
H1-xx = 77 or 78 [MFDI Function Selection = PID SP 1, PID SP 2]
.
This value is a percentage of the maximum output frequency.
0.00%
(0.00 - 100.00%)
shows how the different MFDI
H1-xx
values (
77 and 78
) have an effect on the PID setpoint value.
Table 12.17 Switching of MFDI and PID Setpoint Value
H1-xx = 77
H1-xx = 78
PID Setpoint Value
OFF
OFF
No switch
ON
OFF
b5-58 [PID Setpoint 2]
OFF
ON
b5-59 [PID Setpoint 3]
ON
ON
b5-60 [PID Setpoint 4]
■
b5-61: PID LoLim Select for Trim Mode
No.
(Hex.)
Name
Description
Default
(Range)
b5-61
(119A)
PID LoLim Select for Trim
Mode
Sets the function that adjusts the PID output in relation to the frequency reference.
0
(0, 1)
0 : Disabled
Does not adjust the PID output with the frequency reference.
1 : Enabled
Adjusts the PID output in relation to the frequency reference. The setting value of
b5-62 [PID LoLim Value for
Trim Mode]
sets the lower limit of the post-adjustment value. The maximum output frequency sets the upper limit.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...