482
SIEPCYEUOQ2V01A Q2V Technical Manual
start operation again. When
b5-09 = 1 [Reverse output]
, and the PID feedback is more than setting value of
b5-
94
for a time longer than the setting value of
b5-96
, the drive will exit sleep and start operation again.
•
When
b5-95 = 0 [Setpoint Delta]
:
When
b5-09 = 0
, and the PID feedback is less than the value of
“
PID setpoint value -
b5-94
”
for a time longer
than the value of
b5-96
, the drive will exit sleep and start operation again. When
b5-09 = 1
, and the PID
feedback is more than the value of
“
PID setpoint value +
b5-94
”
for a time longer than the setting value of
b5-
96
, the drive will exit sleep and start operation again.
■
b5-95: EZsleep Wake Mode
No.
(Hex.)
Name
Description
Default
(Range)
b5-95
(0B95)
EZsleep Wake Mode
Sets the wake-up mode to use when exiting Sleep Mode.
0
(0, 1)
0 : Setpoint Delta
1 : Absolute
■
b5-96: EZsleep Wake Time
No.
(Hex.)
Name
Description
Default
(Range)
b5-96
(0B96)
RUN
EZsleep Wake Time
Sets the EZ Wake-up time.
1.0 s
(0.0 - 1000.0 s)
When the PID feedback is less than the value of
b5-94 [EZsleep Wake Level]
continuously for the time set in
b5-
96
, the drive will exit sleep and start operation again.
◆
b6: DWELL FUNCTION
The Dwell function momentarily holds the output frequency at start and stop.
This prevents motor speed loss when you start and stop heavy loads. The Dwell function is also enabled when
backlash on the machine side causes sudden movement at the start of acceleration and deceleration.
At the start of acceleration, the drive uses the output frequency and acceleration time set for the Dwell function to
automatically operate at low speed to minimize the effects of backlash. Then, the drive can accelerate again. The
Dwell function operates the same for deceleration.
For conveyor applications, the Dwell function also lets the drive interlock the output frequency and a delay time
for the holding brake on the load side.
The Dwell function momentarily stops during acceleration to prevent a PM motor from stepping out.
shows how the Dwell function works.
Note:
When you use the Dwell function at stop, set
b1-03 = 0 [Stopping Method Selection = Ramp->Stop]
.
Figure 12.34 Time Chart for the Dwell Function at Start/Stop
■
b6-01: Dwell Ref.@Start
No.
(Hex.)
Name
Description
Default
(Range)
b6-01
(01B6)
Dwell Ref.@Start
Sets the output frequency that the drive will hold momentarily when the motor starts.
0.0
(Determined by A1-02)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...