498
SIEPCYEUOQ2V01A Q2V Technical Manual
◆
C4: TORQUE COMPENSATION
Torque compensation is a function that increases voltage to increase output torque as compensation for
insufficient torque production at start-up or low-speed operation.
Voltage drops due to motor winding resistance cause torque generating voltage to decrease, which causes
insufficient torque. If the main circuit cable connecting the drive and motor is long, this can also cause insufficient
torque due to voltage drops.
Note:
Set the motor parameters and V/f pattern properly before setting
C4 parameters
.
■
C4-01: Trq Comp Gain
No.
(Hex.)
Name
Description
Default
(Range)
C4-01
(0215)
RUN
Trq Comp Gain
Sets the gain for the torque compensation function. Use this parameter value for motor 1 when
operating multiple motors.
Determined by A1-02
(0.00 - 2.50)
For these control methods and states, adjust the setting value.
A1-02 [Control Method]
Status
Adjustment
0 [V/f Control]
8 [EZ Vector]
Torque is not sufficient during low-speed operation of 10 Hz or less.
Increase the setting in 0.05-unit increments.
There is vibration in the motor or the motor hunts when operating the
drive with a light load.
Decrease the setting in 0.05-unit decrements.
The cable length between the drive and motor is too long.
Increase the setting in 0.05-unit increments.
Note:
•
Adjust
C4-01
to make sure that output current is not more than the drive rated current while the drive operates at low speed.
•
When
A1-02 = 2 [OLVector]
, do not change this parameter under normal conditions. Torque accuracy will decrease.
•
When
A1-02 = 5 [PM OLVector]
, do not change this parameter under normal conditions. Setting this value too high can cause
overcompensation and motor oscillation.
•
When
A1-02 = 8 [EZ Vector]
, you cannot change this parameter during drive run.
■
C4-02: Trq Comp Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
C4-02
(0216)
RUN
Trq Comp Delay Time
Sets the torque compensation delay time. Usually it is not necessary to change this setting.
Determined by A1-02
(0 - 60000 ms)
Note:
If
A1-02 = 8 [Control Method = EZ Vector]
, you cannot change the setting while the drive is running.
Set this parameter in these conditions:
•
If there is vibration in the motor, increase the setting.
•
If the motor speed or motor torque response is too slow, decrease the setting.
■
C4-03: Trq Comp@FWD Start
No.
(Hex.)
Name
Description
Default
(Range)
C4-03
(0217)
Trq Comp@FWD Start
Set the amount of torque reference for forward start as a percentage of the motor rated torque.
0.0%
(0.0 - 200.0%)
The torque compensation function is performed using the time constant set in
C4-05 [Trq Comp Time]
.
This is available only when you start the motor with the forward command. Set this parameter to 0.0 to disable
this function.
■
C4-04: Trq Comp@REV Start
No.
(Hex.)
Name
Description
Default
(Range)
C4-04
(0218)
Trq Comp@REV Start
Sets the amount of torque reference for reverse start as a percentage of the motor rated torque.
0.0%
(-200.0 - 0.0%)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...