546
SIEPCYEUOQ2V01A Q2V Technical Manual
Note:
When
A1-02 = 0 [Control Method = V/f Control]
, set
H6-01 = 3 [PI Pulse Train Function = PG Feedback]
to enable this parameter.
■
F1-10: Speed Dev Level
No.
(Hex.)
Name
Description
Default
(Range)
F1-10
(0389)
Speed Dev Level
Sets the detection level of
dEv [Speed Deviation]
as a percentage when the maximum output
frequency is 100%.
10%
(0 - 50%)
When the speed deviation between the frequency reference and the actual motor speed is more than the value set
in
F1-10
for longer than the time set in
F1-11 [Speed Dev Delay Time]
, the drive will detect
dEv
.
Note:
When
A1-02 = 0 [Control Method = V/f Control]
, set
H6-01 = 3 [PI Pulse Train Function = PG Feedback]
to enable this parameter.
■
F1-11: Speed Dev Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
F1-11
(038A)
Speed Dev Delay Time
Sets the length of time that the difference between the frequency reference and speed feedback
must be more than the level in
F1-10
to cause
dEv [Speed Deviation]
.
0.5 s
(0.0 - 10.0 s)
When the speed deviation between the frequency reference and the actual motor speed is more than the value set
in
F1-10 [Speed Dev Level]
for longer than the time set in
F1-11
, the drive will detect
dEv
.
Note:
When
A1-02 = 0 [Control Method = V/f Control]
, set
H6-01 = 3 [PI Pulse Train Function = PG Feedback]
to enable this parameter.
■
F1-14: Enc PGOpen Time for Detection
No.
(Hex.)
Name
Description
Default
(Range)
F1-14
(038D)
Enc PGOpen Time for
Detection
Sets the length of time that the drive must not receive a pulse signal to cause
PGo [Encoder (PG)
Feedback Loss]
.
2.0 s
(0.0 - 10.0 s)
If the drive does not detect ouput pulses from the encoder for the time set in
F1-14
, it will trigger
PGo
.
Note:
•
When
A1-02 = 0 [Control Method = V/f Control]
, set
H6-01 = 3 [PI Pulse Train Function = PG Feedback]
to enable this parameter.
•
Motor speed and load conditions can cause
ov [Overvoltage]
and
oC [Overcurrent]
faults.
◆
F6: COMMUNICATIONS, F7: ETHERNET
F6 and F7 parameters
are used to set the basic communication settings and method of fault detection for the
communication option card. The communication option card parameters include common option card parameters
and communication protocol-specific parameters.
The following table lists the parameters that need to be set for each communication option card.
Refer to the technical manual for each communication option card for more information on installing, wiring, and
configuring the details needed before starting communication.
WARNING!
Sudden Movement Hazard. Do test runs and examine the drive to make sure that the command references are
correct. If you set the command reference incorrectly, it can cause damage to the drive or serious injury or death.
Table 12.30 Correspondence Between Communication Protocols and Parameters (SI-C3, SI-T3, SI-ET3, SI-P3, SI-S3,
and SI-ES3)
Parameter
CC-Link
SI-C3
MECHATROLINK-II
SI-T3
MECHATROLINK-III
SI-ET3
PROFIBUS-DP
SI-P3
CANopen
SI-S3
EtherCAT
SI-ES3
F6-01 to F6-03
x
x
x
x
x
x
F6-04
x
-
-
-
-
-
F6-06 to F6-08
x
x
x
x
x
x
F6-10, F6-11
x
-
-
-
-
-
F6-14
x
x
x
x
x
x
F6-16
x
x
x
x
x
x
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...