H1-26: DI6 Funct.Sel 2
No.
(Hex.)
Name
Description
Default
(Range)
H1-27
(0B76)
DI7 Funct.Sel 2
Sets the second function for MFDI terminal DI7.
0
(1 - 4, 6 - 19F)
When MFDI terminal DI6 activates, it will operate the function set to
H1-06 [DI6 Function Selection]
and the
function set to
H1-26
at the same time.
When the setting value is
0
, the function is disabled.
■
H1-27: DI7 Funct.Sel 2
No.
(Hex.)
Name
Description
Default
(Range)
H1-27
(0B76)
DI7 Funct.Sel 2
Sets the second function for MFDI terminal DI7.
0
(1 - 4, 6 - 19F)
When MFDI terminal DI7 activates, it will operate the function set to
H1-07 [DI7 Function Selection]
and the
function set to
H1-27
at the same time.
When the setting value is
0
, the function is disabled.
■
Modbus MFDI 1 to 3 Function Selection
You can set the function for the MFDI to Modbus register
bit 0 to 2
of
[15C0(Hex.)]
. Use
H1-40 to H1-42 [Mbus
15C0h b0 Input Function to Mbus 15C0h b2 Input Function]
to select the function.
Note:
•
Refer to
H1: DIGITAL INPUTS on page 566
for more information on the virtual digital input setting values.
•
You cannot set values
5 [3-Wire Seq.]
and
20 to 2F [External Fault]
for
H1-40
to
H1-42
.
•
When you will not use
H1-40
to
H1-42
, set them to
0 [Through Mode]
.
■
H1-40: Mbus 15C0h b0 Input Function
No.
(Hex.)
Name
Description
Default
(Range)
H1-40
(0B54)
Mbus 15C0h b0 Input
Function
Selects MFDI function assigned to
bit 0
of the Modbus register
15C0 (Hex.)
.
0
(1 - 4, 6 - 19F)
■
H1-41: Mbus 15C0h b1 Input Function
No.
(Hex.)
Name
Description
Default
(Range)
H1-41
(0B55)
Mbus 15C0h b1 Input
Function
Selects MFDI function assigned to
bit 1
of the Modbus register
15C0 (Hex.)
.
0
(1 - 4, 6 - 19F)
■
H1-42: Mbus 15C0h b2 Input Function
No.
(Hex.)
Name
Description
Default
(Range)
H1-42
(0B56)
Mbus 15C0h b2 Input
Function
Selects MFDI function assigned to
bit 2
of the Modbus register
15C0 (Hex.)
.
0
(1 - 4, 6 - 19F)
◆
MFDI Setting Values
Selects a function set with
H1-01 to H1-07
.
■
0: Through Mode
Setting Value
Function
Description
0
Through Mode
Use this setting for unused terminals or to use terminals in through mode.
Through Mode uses the signal input to the terminal as a digital input for the upper sequence through a
communication option or Modbus communications. This input signal does not have an effect on drive operation.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...