594
SIEPCYEUOQ2V01A Q2V Technical Manual
■
H2-41: Mbus 15E0h b1 Output Function
No.
(Hex.)
Name
Description
Default
(Range)
H2-41
(0B59)
Mbus 15E0h b1 Output
Function
Sets the MFDO for bit 1 of Modbus register 15E0 (Hex.).
F
(0 - 1FF)
■
H2-42: Mbus 15E0h b2 Output Function
No.
(Hex.)
Name
Description
Default
(Range)
H2-42
(0B5A)
Mbus 15E0h b2 Output
Function
Sets the MFDO for bit 2 of Modbus register 15E0 (Hex.).
F
(0 - 1FF)
■
H2-60: NO,NC,CM 2nd Function
No.
(Hex.)
Name
Description
Default
(Range)
H2-60
(1B46)
Expert
NO,NC,CM 2nd Function
Sets the second function for terminal NO/NC-CM. Outputs the logical calculation results of the
terminals assigned to functions by
H2-01 [NO,NC,CM FuncSelection]
.
0
(0 - FF)
■
H2-61: NO,NC,CM Logic Operation
No.
(Hex.)
Name
Description
Default
(Range)
H2-61
(1B47)
Expert
NO,NC,CM Logic
Operation
Sets the logical operation for the functions set in
H2-01 [NO,NC,CM FuncSelection]
and
H2-60
[NO,NC,CM 2nd Function]
.
1
(1 - 9)
Refer to
Output of Logical Operation Results of MFDO on page 588
for more information about the relation
between parameter settings and logical operations.
■
H2-62: NO,NC,CM Min ON-Time
No.
(Hex.)
Name
Description
Default
(Range)
H2-62
(1B48)
Expert
NO,NC,CM Min ON-Time
Sets the minimum ON time that the drive uses to output the logical calculation results from
terminal NO,NC,CM.
0.1 s
(0.0 - 25.0 s)
■
H2-63: DO1 2nd Function
No.
(Hex.)
Name
Description
Default
(Range)
H2-63
(1B49)
Expert
DO1 2nd Function
Sets the second function for terminal DO1-O1C. Outputs the logical calculation results of the
terminals assigned to functions by
H2-02 [DO1-O1C Func Selection]
.
o
(0 - FF)
■
H2-64: DO1 Logic Operation
No.
(Hex.)
Name
Description
Default
(Range)
H2-64
(1B4A)
Expert
DO1 Logic Operation
Sets the logical operation for the functions set in
H2-02 [DO1-O1C Func Selection]
and
H2-63
[DO1 2nd Function]
.
1
(1 - 9)
Refer to
Output of Logical Operation Results of MFDO on page 588
for more information about the relation
between parameter settings and logical operations.
■
H2-65: DO1 Min ON-Time
No.
(Hex.)
Name
Description
Default
(Range)
H2-65
(1B4B)
Expert
DO1 Min ON-Time
Sets the minimum ON time used to output the logical calculation results from terminal DO1-O1C.
0.1 s
(0.0 - 25.0 s)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...