SIEPCYEUOQ2V01A Q2V Technical Manual
595
■
H2-66: DO2 2nd Function
No.
(Hex.)
Name
Description
Default
(Range)
H2-66
(1B4C)
Expert
DO2 2nd Function
Sets the second function for terminal DO2-O2C. Outputs the logical calculation results of the
terminals assigned to functions by
H2-03 [DO2-O2C Func Selection]
.
0
(0 - FF)
■
H2-67: DO2 Logic Operation
No.
(Hex.)
Name
Description
Default
(Range)
H2-67
(1B4D)
Expert
DO2 Logic Operation
Sets the logical operation for the functions set in
H2-03 [DO2-O2C Func Selection]
and
H2-66
[DO2 2nd Function]
.
1
(1 - 9)
Refer to
Output of Logical Operation Results of MFDO on page 588
for more information about the relation
between parameter settings and logical operations.
■
H2-68: DO2 Min ON-Time
No.
(Hex.)
Name
Description
Default
(Range)
H2-68
(1B4E)
Expert
DO2 Min ON-Time
Sets the minimum ON time used to output the logical calculation results from terminal DO2-O2C.
0.1 s
(0.0 - 25.0 s)
◆
MFDO Setting Value
Selects the function configured to a MFDO.
■
0: Through Mode
Setting Value
Function
Description
0
Through Mode
Use this setting for unused terminals or to use terminals in through mode. Also use this setting as the PLC contact output via
Modbus or the communication option. This signal does not function if signals from the PLC are not configured.
■
1: Drive Ready
Setting Value
Function
Description
1
Drive Ready
The terminal activates when the drive is ready and running.
The terminal deactivates in these conditions:
•
When the power supply is OFF
•
During a fault
•
When there is problem with the control power supply
•
When there is a parameter configuration error and the drive cannot operate although there is a Run command
•
When you enter a Run command and it immediately triggers an overvoltage or undervoltage fault because the
drive has an overvoltage or undervoltage fault during stop
•
When the drive is in Programming Mode and will not accept a Run command
■
2: Drive Enable
Setting Value
Function
Description
2
Drive Enable
This terminal activates when the
H1-xx = 1A [Drive Enable]
terminal activates.
■
3: Fault
Setting Value
Function
Description
3
Fault
The terminal activates when the drive detects a fault.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...