SIEPCYEUOQ2V01A Q2V Technical Manual
Apply the primary delay filter to the analog input to enable an analog input signal without the use of high-
frequency noise components. An analog input filter prevents irregular drive control. Drive operation becomes
more stable as the programmed time becomes longer, but it also becomes less responsive to quickly changing
analog signals.
■
H3-14: An.In Term.Enable Sel
No.
(Hex.)
Name
Description
Default
(Range)
H3-14
(041C)
An.In Term.Enable Sel
Sets the enabled terminal or terminals when
H1-xx = 12 [MFDI Function Select = AI Input Sel]
is
ON.
3
(1, 2, 3)
Input signals do not have an effect on terminals not set as targets.
1 : AI1 only
2 : AI2 only
3 : AI1 and AI2
Note:
•
The ON/OFF operation of terminal DIx set in
AI Input Sel [H1-xx = 12]
has an effect on only the analog input terminal selected with
H3-14
.
•
When
H1-xx ≠ 12
, the functions set to terminals AI1 and AI2 are always enabled.
■
H3-16: AI1 Offset
No.
(Hex.)
Name
Description
Default
(Range)
H3-16
(02F0)
AI1 Offset
Sets the offset level for analog signals input to terminal AI1. Usually it is not necessary to change
this setting.
0
(-500 - +500)
Adds the offset value for the analog input value. For voltage input, this parameter will set the offset when a signal
of 0 V is input.
■
H3-17: AI2 Offset
No.
(Hex.)
Name
Description
Default
(Range)
H3-17
(02F1)
AI2 Offset
Sets the offset level for analog signals input to terminal AI2. Usually it is not necessary to change
this setting.
0
(-500 - +500)
Adds the offset value for the analog input value. For voltage input, this parameter will set the offset when a signal
of 0 V is input. For current input, this parameter will set the offset when a signal of
4 mA [H3-09 = 2]
or
0 mA
[H3-09 = 3]
is input.
■
H3-40: 15C1h Input Function
No.
(Hex.)
Name
Description
Default
(Range)
H3-40
(0B5C)
15C1h Input Function
Sets the Modbus AI1 function.
0
(0, 3, 6 - 2F)
You can use the MFAI function from Modbus communications. Use this parameter to set the function. Sets the
input for the function in Modbus register 15C1.
Refer to
for the setting values.
■
H3-41: 15C2h Input Function
No.
(Hex.)
Name
Description
Default
(Range)
H3-41
(0B5F)
15C2h Input Function
Sets the Modbus AI2 function.
0
(0, 3, 6 - 2F)
You can use the MFAI function from Modbus communications. Use this parameter to set the function. Sets the
input for the function in Modbus register 15C2.
Refer to
for the setting values.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for Q2V Series
Page 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Page 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Page 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Page 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...